Draught Measurement With The Control Unit And Analyser Box - TESTO 300 XXL Instruction Manual

Hide thumbs Also See for 300 XXL:
Table of Contents

Advertisement

Measurement menu
1 sec
Function menu
Select "Draught"
Measurement menu
D D r r g g h h t t
Flue gas probe
outside flue
Autom. zeroing
Place probe in flue
Stable reading?
with the control unit and the analyser box
Preparing for measurement
Use the flue gas probe for the draught measurement. The
draught measurement can be conducted before or after a
flue gas measurement.
A draught measurement is only possible with the pump
switched off. The + pressure inlet of the device must be
open!
Do not change between battery and mains operation
during the draught measurement (voltage fluctuations
influence the result of the measurement)!
If you conduct the draught measurement after a flue gas
measurement, a head of pressure exists in the hose after
the pump has stopped, which must be dispelled. This
occurs within approx. 30 seconds.
Remove any traces of condensation in the flue gas probe
(shake out the probe with the tip towards the floor).
Start measurement
1 Activate the function menu with the
the function keys. Select function key
and confirm with
2 Start measurement with
Sensor zeros automatically, probe must be outside
the flue.
3 Place probe in flue.
Negative sign indicates vacuum,
positive sign indicates pressure in the flue.
4 Display of the current reading.
Result
Example measurement
Draught measurement
Draught
.
.
Draught
key and one of
with
25

Advertisement

Table of Contents
loading

Table of Contents