Main menu Input
for analyser box
Measurement menu
Select "Input"
Select "Spot (smoke) number/ WTT"
Select the menu
Enter
"Smoke number 1"
"Smoke number 2"
"Smoke number 3"
"Heat carrier temp."
Select number
Confirm selection
76
Spot number / Oil derivative / Heat carrier temperature
Note:
Enter spot number and oil drivatives only for oil fuels and
propane.
1 Connect analyse box to control unit; switch on control
unit.
2 Change to main menu with key
3 From Main menu - Input – Smoke number/WTT (HCT)
- Smoke number 1 – enter value
- Smoke number 2 – enter value
- Smoke number 3 – enter value
- Heat carrier temp. - enter value
With the cursor keys
in the numeric block and confirm with key
4 Accept the respectively entered value with function key
.
E E n n d d
5 When the heat carrier temperature has been entered and
confirmed, an automatic branch is made to the "Oil
derivative" menu.
6 Select "Oil derivative?", "No / Yes". Branch to the "Info"
menu with functional key
7 Return to the measurement menu with key
Set comes into
effect
E E n n d d
Oil derivative no/yes
.
select numbers
.
Accept the settings
O O K K
Display info
Measurement menu
.
.

Advertisement