X5(
=
USB audio type
0 = None, input is muted
1 = LPCM 2-Ch
=
USB standard
X6)
0 = None, no host
1 = USB 1.1
2 = USB 2.0
3 = USB 3.0
X6!
=
Video signal status
0 = Video not detected
1 = Video or detected
X6@
=
Input HDCP authorized
0 = Input HDCP Authorized disabled (default)
1 = Input HDCP Authorized enabled
X6(
=
(Ethernet only) Number of seconds (stated in tens) before timeout on IP
connections
Minimum = 1 (10 seconds)
Maximum = 65000 (650,000 seconds)
Default = 30 (300 seconds)
Each step = 10 seconds
The response contains leading zeros.
If no data is received during the timeout period, the Ethernet connection is
closed. When the unit is connected via RS-232 or USB, only global timeout
commands apply. Anything else returns an E13 error code.
=
Local date and time
X7)
Set format: MM/DD/YY‑HH:MM:SS
Example: 06/21/15‑10:54:00
View format: Www {day of the week}, DD Mmm YYYY HH:MM:SS
Example: Fri, 26 Sep 2015 18:19:33
=
Greenwich Mean Time (GMT) offset value (-12:00 through 14:00) in hours
X7!
and minutes (hh:mm)
X7@
=
A 2- to 6-digit code, such as "PST" for GMT - 8.00
X7#
=
UTC offset and location name, such as (UTC‑08:00) Pacific Time for PST
X7$
=
IP address (nnn.nnn.nnn.nnn). Leading zeros in each of the four fields
are optional in setting values and are suppressed in returned values.
Factory default address (when DHCP is turned off) is
MediaPort 200 • Remote Configuration and Control
.
192.168.254.254