X12#
=
Type of change to monitor (
= Off (no trigger)
0
= Push to mute level trigger: mute active low, unmute high.
1
= Push to talk level trigger: unmute active low, mute high.
2
= Mic mute edge trigger: high to low (mute), low to high (unmute)
3
= Mic mute edge trigger: high to low (unmute), low to high (mute)
4
= Mic mute toggle trigger: high to low
5
= Mic mute toggle trigger: low to high
6
= Increment group master 1 level trigger: low increments group, 1.0 dB
7
= Decrement group master 1 level trigger: low decrements group, 1.0 dB
8
= Preset toggle edge trigger: high to low (recalls preset 13), low to high
9
(recalls preset 14).
= Preset toggle edge trigger: high to low (recalls preset 15), low to high
10
(recalls preset 16).
X12$
=
Digital output: 1 or 2
X12%
=
Digital output control mode:
= Output high (default)
0
= Output low
1
= Follow mute (when muted, output is high)
2
= Follow inverted mute (when unmuted, output is high)
3
= Blink, following input 1 trigger (either increment/decrement or preset
4
recall)
5 = Blink, following input 2 trigger (either increment/decrement or preset
recall)
X12^
=
Group master name. Maximum length is 16 characters. Invalid characters
include: =
` , @ ' [ ] { } X ~ " ; : | \ ?
-
)
0
10
MediaPort 200 • Remote Configuration and Control