16. Appendix 3 - Wiring Diagrams

16.2 AIM 4-20 mA with 2 Wire Device Powered by AIM mA

2 Wire Detector
4-20mA
2 Wire Detector
4-20mA
2 Wire Detector
4-20mA
2 Wire Detector
4-20mA
Note:
1. For all shielded cables, shield (screen) should be connected to Earth tag bar/bus bar provided in Touchpoint Pro enclosure.
Recommended Cable:
2 Core, Twisted, Mesh Type
Shielded, 1.5mm
2
or 2.5mm
2
212
Operating Instructions
AIM mA Module
Input 1
+24VDC
+V
1
SIG
Channel 1
2
101 Ω
-V
3
0VDC
E
Input 2
+24VDC
+V
4
SIG
Channel 2
5
101 Ω
-V
6
0VDC
Input 3
+24VDC
+V
7
SIG
Channel 3
8
101 Ω
-V
9
0VDC
Input 4
+24VDC
+V
10
Channel 4
SIG
11
101 Ω
-V
12
0VDC
Touchpoint Pro