Show Rmon - Cisco MDS 9000 series Command Reference Manual

Hide thumbs Also See for MDS 9000 series:
Table of Contents

Advertisement

show rmon

S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
show rmon
To display the remote monitoring (RMON) configuration, use the show rmon command.
Syntax Description
alarms
events
hcalarms
logs
Defaults
None.
Command Modes
EXEC mode.
Command History
Release
2.0(x)
2.1(2)
3.0(1)
Usage Guidelines
To configure a high capacity RMON alarm
Examples
The following example displays the configured RMON alarms.
switch# show rmon alarms
Alarm 20 is active, owned by test
Monitors 1.3.6.1.2.1.2.2.1.16.16777216 every 256000 second(s)
Taking delta samples, last value was 17
Rising threshold is 15, assigned to event 1
Falling threshold is 0, assigned to event 0
On startup enable rising or falling alarm
The following example displays the configured RMON events.
switch# show rmon events
Event 2 is active, owned by Test2
Description is CriticalErrors
Event firing causes log and trap to community eventtrap, last fired 1
The following example displays the high capacity RMON alarms.
switch# show rmon hcalarms
High Capacity Alarm 10 is active, owned by Testuser
Monitors 1.3.6.1.2.1.31.1.1.1.6.16785408 every 300 second(s)
Taking absolute samples, last value was 0 (valuePositive)
Rising threshold low is 4294967295 & high is 15 (valuePositive)
Cisco MDS 9000 Family Command Reference
22-278
show rmon {alarms | events | hcalarms | logs}
Displays the configured RMON alarms.
Displays the configured RMON events.
Displays the high capacity (HC) RMON alarms.
Displays the RMON event logs.
Modification
This command was introduced.
Addedthe logs option.
Added the hcalarms option.
,
use the CISCO-HC-ALARM-MIB.
OL-8413-07, Cisco MDS SAN-OS Release 3.x
Chapter 22
Show Commands

Advertisement

Table of Contents
loading

Table of Contents