Table 6-3 ADA-L Unit Switch Settings (Continued)
Switch
Dip
Switches
(DSW)
Do not connect T1 and T2 when DSW switches 3 and 4 are On.
.
11.3.2

Installing the ADA-L UNIT

Perform the following steps to connect the ADA-L UNIT to the
Bottom Option Interface located underneath the DTL/ITL multiline
terminal.
Only one ADA-L UNIT can be installed at a time.
.
1.
Unplug the line cord from the keyset.
2.
Turn the DTL/ITL multiline terminal upside down.
3.
Lower the tilt leg to the first position (refer to
Separate Tilt Leg from Leg
Tilt Leg
Output Hook Signal to External Device
DSW 1
On = Output
Off = No Output (Default)
Record Confirmation Tone
DSW 2
On = Tone On
Off = Tone Off (Default)
DSW 3
Use T1/T2
and
On = Disable (Default)
DSW 4
Off = Enable
To prevent possible damage to the ADA-L
UNIT or the DTL/ITL multiline terminal
during installation or removal, disconnect
the line cord/LAN cable and the AC/DC
adapter from the DTL/ITL multiline terminal.
Support).
Figure 6-24 Separate Tilt Leg from Leg Support
Description/Settings
Figure 6-24
Issue 1.0