Installation; Pz-8Dlcb Daughter Board Cable Connection - NEC Univerge SV8100 System Hardware Manual

Full-featured ip based communications system
Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
System Hardware Manual
4.2.2

Installation

The PZ-8DLCB is installed on the CD-8DLCA. To install:
1.
Connect the PZ-8DLCB to the CN2 connector on the
CD-8DLCA blade. Refer to
page 4-37
2.
Install the CD-8DLCA into a slot.
3.
Each CNx01 connector (CN101, CN201, CN301, CN401) is
used to connect up to four digital extensions.
4.2.3

PZ-8DLCB Daughter Board Cable Connection

The PZ-8DLCB blade has connections for CN301 and CN401 Refer
to
Figure 4-15 CD-16DLCA Blade
The following tables show the cable connections of the two RJ-61
connectors on the PZ-8DLCB.
Figure 4-14 CD-8DLCA Blade on
for the location of the connectors on the blade.
for connector locations.
Table 4-21PZ-8DLCB CN301 Connection
RJ-61 Cable Connector
CN301 (ports 9~12)
Issue 1.0
Pin No.
Connection
1
(T4) Tip for port 12
2
(T3) Tip for port 11
3
(T2) Tip for port 10
4
(R1) Ring for port 9
5
(T1) Tip for port 9
6
(R2) Ring for port 10
7
(R3) Ring for port 11
8
(R4) Ring for port 12
4 - 43