Installing A Door Box; Section 4 Door Box - NEC Univerge SV8100 System Hardware Manual

Full-featured ip based communications system
Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
D
S
4
OOR
ECTION
4.1
System Hardware Manual
B
OX

Installing a Door Box

A PGD(2)-U10 ADP is required for this option.
The Door Box is a self-contained, water-resistant, Intercom unit typically used
to monitor an entrance door. A visitor at the door can press the Door Box call
button (like a door bell). The Door Box then sends chime tones to all
extensions programmed to receive chimes. The system can have up to eight
Door Boxes.
Each PGD(2)-U10 ADP audio output can optionally support two analog Door
Boxes. In addition, you can connect each circuit control relay to an electric
door strike. This allows an extension user to remotely activate the door strike
while talking to a visitor at the Door Box. The control relays are normally open.
The CD-CP00 also provides one relay. This relay is defined as a general
purpose relay in programming (Program 10-21-01 = 3). The CD-CP00 relay 0
is assigned to the door box extension port in Program10-05-01. When the
relay on the PGD(2)-U10 ADP is used, there is no need to assign the relay to
the Door Box – simply connect the relay as detailed in the steps below for the
Door Box used. The relays on the
PGD(2)-U10 ADPs are numbered 5-8.
The relay closes when the Door Box/external page zone is called. The maximum applied
.
voltage is 24vDC at 0.5A for each contact.
A PGD(2)-U10 ADP circuit used for an analog Door
Box cannot also be used for External Paging.
1.
Make sure the jumper in the PGD(2)-U10 ADP for the associated Door
Box is set correctly. (Refer to Figure 6-4
on page 6-4).
Settings
2.
If a line cord was not previously connected to the PGD(2)-U10 ADP,
complete Steps 3-6. Otherwise, skip to Step 7.
3.
Install a modular jack for each PGD(2)-U10 ADP. For each module, run
one-pair 24 AWG station cable from the cross-connect block to a
modular jack. Ground the unused pair.
4.
Terminate the extension leads to GRN/RED of the modular jack.
Terminate the unused leads to the jack.
5.
Install bridging clips as required.
6.
Plug a modular line cord from the mod jack to the CN1 connector on the
PGD(2)-U10 ADP.
PGD(2)-U10 ADP Jumper
Issue 1.0
6 - 11