100
CoDeSys 2.3 Runtime Environment
3.
Enter a name for the I/O-IPC in which the PLC program is to be loaded
(e.g., I/O-IPC_Area1) in the "Name" field and click on [OK].
Figure 15: Creating a new communication channel 2
4.
Enter the IP address of your I/O-IPC in the "Address" field in the
"Communication Parameters" window and then press the enter key on your
PC keyboard. To close the window, click in the window on [OK].
To select an already created I/O-IPC, select it in the left window and then
click on [OK].
Figure 15: Creating a new communication channel
5.
Transfer the PLC program by clicking on Online in the menu bar and select
Login.
6.
Remember that the I/O-IPC's Run/Stop switch must be in the "Run"
position.
7.
Start the PLC program by clicking on Online in the menu bar and selecting
Run.
WAGO-I/O-SYSTEM 750
I/O-IPC-C10E, CANopen Master