▼ To Disable Line Cards

To disable standby power and IPMB buses for a line card, type this command:
# disableboard lc slot
where slot is the slot number of the line card from
When a line card is disabled, the Standby LED on that line card goes out.

▼ To Enable Line Card IPMB Buses

To enable an IPMB bus on a line card, type this command:
# enableipmb lc slot bus
where:
slot is the slot number of the line card from
bus is either a or b

▼ To Disable Line Card IPMB Buses

To disable an IPMB bus on a line card, type this command:
# disableipmb lc slot bus
where:
slot is the slot number of the line card from
bus is either a or b

▼ To Enable Line Card Standby Power

To enable standby power on a line card, type this command:
# enablestby lc slot
where slot is the slot number of the line card from
.
TABLE 9-1
TABLE 9-1
TABLE 9-1
.
TABLE 9-1
Chapter 9
Installing Line Cards
79