Summary of Contents for Sun Microsystems Sun StorEdge
Page 1
Caution – Before you install the switch FRU, use the following procedure to confirm that the firmware version of the FRU matches the firmware version of the Sun StorEdge Network 1 Gb or 2 Gb FC switch (hereafter referred to as the “FC switch”) it is replacing.
Page 2
d. Log in to the FC switch. On a 1 Gb switch, type: Username: root Password: ma31_glw On a 2 Gb switch, type: Username: admin Password: password 2. Use the show version command to display the firmware version. In the following 2 Gb FC switch example, the firmware version is V2.0.0.x. SANbox2 #>...
Page 3
To Remove and Replace the FC Switch Refer to the Switch Management User’s Manual for your product for instructions about how to remove and replace the FC switch. These manuals are listed in Step 3 of “To Confirm the Existing FC Switch Firmware”.
Page 4
Sun suppliers. Portions may be derived from Berkeley BSD systems, licensed from U. of CA. Sun, Sun Microsystems, the Sun logo, Sun StorEdge, and Solaris are trademarks or registered trademarks of Sun Microsystems, Inc. in the U.S. and in other countries. All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International, Inc.
Need help?
Do you have a question about the Sun StorEdge and is the answer not in the manual?
Questions and answers