Contents About this book How this book is organized Taking advantage of this book’s hypertext features Understanding the conventions used in this book Obtaining the latest information and resources Commenting on this book Getting to know the switch Understanding the front panel Understanding the rear panel Understanding switch port numbering Installing the switch in a rack ▼ Installing the switch in a 19‐inch equipment rack 316198301AC SL8500 Model 4199516XX Redundant Power Switch Rack Installation Guide...
Page 4
SL8500 Model 4199516XX Redundant Power Switch Rack Installation Guide Feb 2010...
About this book This book is intended for anyone who has to install a SL8500 Model 4199516XX Redundant Power Switch (where XX stands for the identifying digits of submodels in the Compliance Model 4199516XX family). The remainder of this preface explains how you can use this book most effectively and how you can obtain updated or supplementary documentation. How this book is organized The document is task‐oriented, organized around the work you have to do rather than around the features or components of the product. Chapters and sections generally begin with a list of tasks covered. Tasks are presented in order, and the steps in each process are numbered, in the sequence in which they are to be performed. Conditional steps (steps that you perform only in specified circumstances) begin with the condition (“If A ...”) and end with the corresponding action (“... do B”); if the condition does not apply, you simply skip the step. Each task ends with a reference to the next task in the sequence: Next task: “Installing ...” on page 3. When the setup process branches, the task ends with conditional alternatives: Next task: If the customer does not plan to run the management console from a host on ■ the local area network (LAN), press Skip, and go to the next task. Otherwise, carry out the procedure “Configuring the Ethernet LAN” on ■ page 57. When you have finished a task or sequence of tasks, this is clearly noted in the document: Stop here. v SL8500 Model 4199516XX Redundant Power Switch Rack Installation Guide 316198301AC...
To minimize the time that you spend switching between publications or between major sections of the document, we have made an effort to avoid cross references to external information wherever possible. If you need to have a figure, a table, or a procedure, it should always be, at worst, on a neighboring page. Taking advantage of this book’s hypertext features If you choose to view this book online, rather than in printed form, you can jump quickly to any part of the book by clicking on the corresponding entry under the Bookmarks tab on the left side of the Adobe Acrobat interface. In addition, clicking on entries in the table of contents, cross references, or references to subsequent tasks will take you directly to the indicated part of the document. You can then use the back arrow on the Adobe Acrobat Reader to return, if desired, to the point you left. In addition, clicking on most Uniform Resource Locators (URLs) and on most references to online resources will open your default web browser to the corresponding web page. You can, if necessary, obtain a required download immediately (be aware, however, URLs to specific pages change frequently and may not always be accurate). Understanding the conventions used in this book The table below illustrates the conventions that represent literal and variable values, commands, and property names in this book. Convention Meaning Examples Fixed‐width text is used for literal Edit your.login file. AaBbCc123 values, including names of commands, Use ls -a to list files, directories, literal computer files. inputs/outputs, and Uniform Resource % You have mail. Locators (URLs) AaBbCc123 Oblique text is used for variables that ...
ABOUT THIS BOOK Convention Meaning Examples ■ Bulleted paragraphs indicate lists of alternatives or components. A commandline prompt [iasd01-no1]root# Keys on the keyboard Tab, Shift, A A combination of keys on the Ctrl-Alt-Del, keyboard, pressed at the same time. Alt-0169 Obtaining the latest information and resources Obtain the latest Sun documentation from <docs.sun.com>. Always check the documentation portal for updates to this document before proceeding. Documents distributed by other means, such as CDROM, may not reflect the latest changes to appliance hardware, software, and services. Commenting on this book Sun welcomes your comments and suggestions for improving this book. Contact us at dsc-customer-feedback@sun.com.. Please include the title, part number, issue date, and revision: SL8500 Model 4199516XX Redundant Power Switch Rack Installation Guide, part number 316198301 (Feb 2010 Revision AC). 316198301AC About this book...
Page 8
viii SL8500 Model 4199516XX Redundant Power Switch Rack Installation Guide Feb 2010...
C H A PT E R Getting to know the switch The SL8500 Model 4199516XX Redundant Power Switch is an Ethernet switch with redundant, dual power supplies. This feature makes the switch ideal whenever high‐ availability LAN connectivity is desired. The switch offers the following additional features: thirty‐two 10/100 Base‐T ports ■ two 10/100/1000 Base‐T ports ■ requires no software or processor intervention ■ fits standard, 19‐inch racks. ■ The remainder of this introduction describes the physical layout, status indicators, power connections, and port numbering scheme of the switch. See the following sections for details: “Understanding the front panel” on page 2 ■ “Understanding the rear panel” on page 3 ■ “Understanding switch port numbering” on page 3. ■ 316198301AC SL8500 Model 4199516XX Redundant Power Switch Rack Installation Guide Sun Confidential...
Understanding the front panel The front, port‐side panel of the switch holds the thirty‐two 10/100 Base‐T ports below) and the two 10/100/1000 Base‐T ports ( ). The two redundant power supplies reside inside the case behind the cooling holes in the top panel of the case ( Three light‐emitting diodes (LEDs) display the current power state of the switch. Amber warning LEDs light up to indicate faults on power supplies 0 ( above) and 1 ( ). A green LED lights whenever the system has power ( Standard port LEDs display the link status of each port. A green LED on the left side of the port glows green when the link is operational ( above). An amber LED to the right of the port blinks when the link is actively transmitting or receiving ( SL8500 Model 4199516XX Redundant Power Switch Rack Installation Guide SL8500 Model 4199516XX Redundant Power Switch Rack Installation Guide Feb 2010 Feb 2010...
Understanding the rear panel The rear, non‐port‐side of the switch holds only the power‐cord receptacles for power supplies 0 ( below) and 1 ( ). The rest of the panel is taken up by ventilation openings for the internal circuitry ( Understanding switch port numbering The thirty‐two 10/100 Base‐T ports are arranged in blocks of eight, with the odd numbers (starting with 1) on the bottom and the evens on the top ( below). The two 10/100/1000 Base‐T ports are located to the right of 10/100 Base‐T ports, with port A1 on the bottom and A2 on the top ( 10 12 14 16 18 20 22 24 26 28 30 32 25 27 29 31 11 13 15 17 19 21 23 316198301AC Chapter 1 Getting to know the switch...
Page 12
SL8500 Model 4199516XX Redundant Power Switch Rack Installation Guide SL8500 Model 4199516XX Redundant Power Switch Rack Installation Guide Feb 2010 Feb 2010...
C H A PT E R Installing the switch in a rack The SL8500 Model 4199516XX Redundant Power Switch fits any standard, 19‐inch rack. To install the switch, proceed as follows. ▼ Installing the switch in a 19‐inch equipment rack 1. If your rack requires cage nuts, install one nut in the upper and lower mounting holes of the selected RU on both the left and right posts of the rack. 2. In the selected RU, position the switch horizontally and with the ventilation opening facing up ( below). Caution – for safety and regulatory compliance reasons, the switch must be installed in the upright, horizontal position described. 316198301AC SL8500 Model 4199516XX Redundant Power Switch Rack Installation Guide...
Page 14
3. Insert a mounting screw into each of the mounting holes in the mounting brackets on the front of switch ( above), and tighten each screw to securely fasten the switch to the rack ( 4. To use the redundant power feature, connect a power cord to each of the two redundant power supplies ( below) and then plug each power cord into an independent source of power. For example, to provide full redundancy, you could plug the two cords directly into two independent supply circuits or into two, separate, rack‐mounted power distribution units (PDUs) that are themselves connected to independent supply circuits. 5. If you do not require fully redundant power, connect one of the two power cords above) to one of the two power supplies and plug the cord into a rack‐mounted power distribution unit (PDU) or room power. Note that an unconnected power supply will light up the corresponding amber fault LED. The switch is installed in the rack and ready for network cabling. Stop here. SL8500 Model 4199516XX Redundant Power Switch Rack Installation Guide SL8500 Model 4199516XX Redundant Power Switch Rack Installation Guide Feb 2010 Feb 2010...