  • Page 1 Sun StorageTek™ SL8500 Model 4199516XX Redundant Power Switch Rack Installation Guide Sun Microsystems, Inc. www.sun.com Part No. 316198301 Feb 2010, Revision AC Please submit comments about this document at http://docs.sun.com/app/docs/doc/316198301ACl=en...
  • Page 2 Copyright © 2009  Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, U.S.A. All rights reserved. Sun, Sun Microsystems, the Sun logo and Sun StorageTek are trademarks or registered trademarks of Sun Microsystems, Inc. or its subsidiaries,  in the U.S. and other countries. DOCUMENTATION IS PROVIDED ʺAS ISʺ AND ALL EXPRESS OR IMPLIED CONDITIONS, REPRESENTATIONS AND WARRANTIES,  INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON‐INFRINGEMENT,  ARE DISCLAIMED, EXCEPT TO THE EXTENT THAT SUCH DISCLAIMERS ARE HELD TO BE LEGALLY INVALID.  Copyright © 2009 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, États‐Unis. Tous droits réservés. Sun, Sun Microsystems, le logo Sun et Sun StorageTek sont des marques de fabrique ou des marques enregistrées de Sun Microsystems, Inc. ou  ses filiales, aux États‐Unis et dans dʹautres pays. LA DOCUMENTATION EST FOURNIE ʺEN LʹÉTATʺ ET TOUTES AUTRES CONDITIONS, DECLARATIONS ET GARANTIES EXPRESSES  OU TACITES SONT FORMELLEMENT EXCLUES, DANS LA MESURE AUTORISEE PAR LA LOI APPLICABLE, Y COMPRIS NOTAMMENT  TOUTE GARANTIE IMPLICITE RELATIVE À LA QUALITE MARCHANDE, À LʹAPTITUDE À UNE UTILISATION PARTICULIERE OU À  LʹABSENCE DE CONTREFAÇON.
  • Page 3: Table Of Contents

    Contents About this book  How this book is organized  Taking advantage of this book’s hypertext features  Understanding the conventions used in this book  Obtaining the latest information and resources  Commenting on this book  Getting to know the switch  Understanding the front panel  Understanding the rear panel  Understanding switch port numbering  Installing the switch in a rack  ▼ Installing the switch in a 19‐inch equipment rack  316198301AC SL8500 Model 4199516XX Redundant Power Switch Rack Installation Guide...
  • Page 4 SL8500 Model 4199516XX Redundant Power Switch Rack Installation Guide Feb 2010...
  • Page 5: About This Book

    About this book This book is intended for anyone who has to install a SL8500 Model 4199516XX  Redundant Power Switch (where XX stands for the identifying digits of submodels  in the Compliance Model 4199516XX family). The remainder of this preface explains  how you can use this book most effectively and how you can obtain updated or  supplementary documentation. How this book is organized The document is task‐oriented, organized around the work you have to do rather than  around the features or components of the product. Chapters and sections generally  begin with a list of tasks covered. Tasks are presented in order, and the steps in each  process are numbered, in the sequence in which they are to be performed.  Conditional steps (steps that you perform only in specified circumstances) begin  with the condition (“If A ...”) and end with the corresponding action (“... do B”); if  the condition does not apply, you simply skip the step. Each task ends with a  reference to the next task in the sequence:        Next task: “Installing ...” on page 3. When the setup process branches, the task ends with conditional alternatives:        Next task:  If the customer does not plan to run the management console from a host on  ■ the local area network (LAN), press Skip, and go to the next task. Otherwise, carry out the procedure “Configuring the Ethernet LAN” on  ■ page 57. When you have finished a task or sequence of tasks, this is clearly noted in the  document:        Stop here.  v SL8500 Model 4199516XX Redundant Power Switch Rack Installation Guide 316198301AC...
  • Page 6: Taking Advantage Of This Book's Hypertext Features

    To minimize the time that you spend switching between publications or between  major sections of the document, we have made an effort to avoid cross references to  external information wherever possible. If you need to have a figure, a table, or a  procedure, it should always be, at worst, on a neighboring page. Taking advantage of this book’s hypertext features If you choose to view this book online, rather than in printed form, you can jump  quickly to any part of the book by clicking on the corresponding entry under the  Bookmarks tab on the left side of the Adobe Acrobat interface. In addition, clicking  on entries in the table of contents, cross references, or references to subsequent tasks  will take you directly to the indicated part of the document. You can then use the  back arrow on the Adobe Acrobat Reader to return, if desired, to the point you left.  In addition, clicking on most Uniform Resource Locators (URLs) and on most  references to online resources will open your default web browser to the  corresponding web page. You can, if necessary, obtain a required download  immediately (be aware, however, URLs to specific pages change frequently and may  not always be accurate).  Understanding the conventions used in this book The table below illustrates the conventions that represent literal and variable values,  commands, and property names in this book. Convention Meaning Examples Fixed‐width text is used for literal  Edit your.login file. AaBbCc123 values, including names of commands,  Use ls -a to list  files, directories, literal computer  files. inputs/outputs, and Uniform Resource  % You have mail. Locators (URLs)   AaBbCc123 Oblique text is used for variables that ...
  • Page 7: Obtaining The Latest Information And Resources

    ABOUT THIS BOOK Convention Meaning Examples ■     Bulleted paragraphs indicate lists of  alternatives or components. A commandline prompt [iasd01-no1]root# Keys on the keyboard Tab, Shift, A A combination of keys on the  Ctrl-Alt-Del,  keyboard, pressed at the same time. Alt-0169 Obtaining the latest information and resources Obtain the latest Sun documentation from <docs.sun.com>. Always check the  documentation portal for updates to this document before proceeding. Documents  distributed by other means, such as CDROM, may not reflect the latest changes to  appliance hardware, software, and services. Commenting on this book Sun welcomes your comments and suggestions for improving this book. Contact us  at dsc-customer-feedback@sun.com.. Please include the title, part number, issue  date, and revision: SL8500 Model 4199516XX Redundant Power Switch Rack Installation  Guide, part number 316198301 (Feb 2010 Revision AC). 316198301AC About this book...
  • Page 8 viii SL8500 Model 4199516XX Redundant Power Switch Rack Installation Guide Feb 2010...
  • Page 9: Getting To Know The Switch

    C H A PT E R Getting to know the switch The SL8500 Model 4199516XX Redundant Power Switch is an Ethernet switch with  redundant, dual power supplies. This feature makes the switch ideal whenever high‐ availability LAN connectivity is desired. The switch offers the following additional  features: thirty‐two 10/100 Base‐T ports ■ two 10/100/1000 Base‐T ports ■ requires no software or processor intervention ■ fits standard, 19‐inch racks.  ■ The remainder of this introduction describes the physical layout, status indicators,  power connections, and port numbering scheme of the switch. See the following  sections for details: “Understanding the front panel” on page 2 ■ “Understanding the rear panel” on page 3 ■ “Understanding switch port numbering” on page 3. ■ 316198301AC SL8500 Model 4199516XX Redundant Power Switch Rack Installation Guide Sun Confidential...
  • Page 10: Understanding The Front Panel

    Understanding the front panel The front, port‐side panel of the switch holds the thirty‐two 10/100 Base‐T ports   below) and the two 10/100/1000 Base‐T ports ( ). The two redundant power  supplies reside inside the case behind the cooling holes in the top panel of the  case ( Three light‐emitting diodes (LEDs) display the current power state of the switch.  Amber warning LEDs light up to indicate faults on power supplies 0 (  above)  and 1 ( ). A green LED lights whenever the system has power ( Standard port LEDs display the link status of each port. A green LED on the left side  of the port glows green when the link is operational (  above). An amber LED to the  right of the port blinks when the link is actively transmitting or receiving ( SL8500 Model 4199516XX Redundant Power Switch Rack Installation Guide SL8500 Model 4199516XX Redundant Power Switch Rack Installation Guide Feb 2010 Feb 2010...
  • Page 11: Understanding The Rear Panel

    Understanding the rear panel The rear, non‐port‐side of the switch holds only the power‐cord receptacles for  power supplies 0 (  below) and 1 ( ). The rest of the panel is taken up by  ventilation openings for the internal circuitry ( Understanding switch port numbering The thirty‐two 10/100 Base‐T ports are arranged in blocks of eight, with the odd  numbers (starting with 1) on the bottom and the evens on the top (  below). The  two 10/100/1000 Base‐T ports are located to the right of 10/100 Base‐T ports, with  port A1 on the bottom and A2 on the top ( 10 12 14 16 18 20 22 24 26 28 30 32 25 27 29 31 11 13 15 17 19 21 23 316198301AC Chapter 1 Getting to know the switch...
  • Page 12 SL8500 Model 4199516XX Redundant Power Switch Rack Installation Guide SL8500 Model 4199516XX Redundant Power Switch Rack Installation Guide Feb 2010 Feb 2010...
  • Page 13: Installing The Switch In A Rack

    C H A PT E R Installing the switch in a rack The SL8500 Model 4199516XX Redundant Power Switch fits any standard, 19‐inch  rack. To install the switch, proceed as follows. ▼ Installing the switch in a 19‐inch equipment rack 1. If your rack requires cage nuts, install one nut in the upper and lower mounting  holes of the selected RU on both the left and right posts of the rack. 2. In the selected RU, position the switch horizontally and with the ventilation  opening facing up (  below). Caution – for safety and regulatory compliance reasons, the switch must be  installed in the upright, horizontal position described.  316198301AC SL8500 Model 4199516XX Redundant Power Switch Rack Installation Guide...
  • Page 14 3. Insert a mounting screw into each of the mounting holes in the mounting brackets  on the front of switch (  above), and tighten each screw to securely fasten the  switch to the rack ( 4. To use the redundant power feature, connect a power cord to each of the two  redundant power supplies (  below) and then plug each power cord into an  independent source of power. For example, to provide full redundancy, you could plug the two cords directly into  two independent supply circuits or into two, separate, rack‐mounted power  distribution units (PDUs) that are themselves connected to independent supply  circuits. 5. If you do not require fully redundant power, connect one of the two power cords   above) to one of the two power supplies and plug the cord into a rack‐mounted  power distribution unit (PDU) or room power. Note that an unconnected power supply will light up the corresponding amber fault  LED.  The switch is installed in the rack and ready for network cabling. Stop here. SL8500 Model 4199516XX Redundant Power Switch Rack Installation Guide SL8500 Model 4199516XX Redundant Power Switch Rack Installation Guide Feb 2010 Feb 2010...