Sun Microsystems Datacenter Switch 3456 Manuals
Manuals and User Guides for Sun Microsystems Datacenter Switch 3456. We have
2
Sun Microsystems Datacenter Switch 3456 manuals available for free PDF download: Installation Manual, Service Manual
Sun Microsystems Datacenter Switch 3456 Installation Manual (125 pages)
Brand:
Sun Microsystems
| Category:
Switch
| Size: 7 MB
Table of Contents
Table of Contents
3
Preface
11
Typographic Conventions
12
Related Documentation
12
1 Cautions and Considerations
15
Chassis Weight
15
Moving the Chassis
15
Loading by the Chassis
16
Chassis Activity Dimensions
17
Heat Considerations
17
Air Temperature
17
Surface Temperature
18
Other Objects' Temperatures
18
Hot and Cold Aisles
18
Electrical Considerations
18
Main Power
18
Bus Power
19
Pin Power
19
2 Partial Configuration
21
Complete and Base Configurations
21
Configuration Considerations
22
Filler Panels
22
Line Card Distribution
22
Power Supplies
22
Component Distribution
23
3 Preparing for Installation
25
Final Location Checklists
25
Power Checklist
25
Network Checklist
26
Cabling Checklists
26
Power Cabling Checklist
26
Network Cabling Checklist
26
Spacing Checklist
26
Loading Checklist
27
Environmental Checklist
27
Personnel Checklist
27
Tools Checklists
27
Installation Tools Checklist
28
Administration Tools Checklist
28
Maintenance Tools Checklist
28
Path to Final Location
29
Security Systems
29
Signage
29
Carpets
29
Grades
30
Elevators
30
Doors
30
Thresholds and Gaps
31
Path
31
Surface
31
Turns
31
Receiving Area
32
Equipment
32
Cleanliness
32
Personnel
32
Number of People
33
Tasks and Roles
33
Mindset
34
Safety
34
Methodical Approach
34
Diligent Attitude
35
Installation and Maintenance Tools
35
Standard Tools
35
4 Installation Sequence
37
5 Unpacking the Chassis
39
To Remove Shipping Crate Components
40
To Remove the Plastic Envelope
43
To Fit the Ramp
43
To Unsecure the Chassis
44
To Roll out the Chassis
45
6 Installing the Chassis
50
To Move to the Final Location
50
To Level the Chassis
51
To Secure the Chassis
54
To Remove the Power Supply Filler Panels
54
To Remove the Line Card Filler Panels
55
To Install the Line Card Filler Panels
56
Inspecting the Chassis
58
To Verify Electrical Leakage
58
To Verify Electrical Continuity
59
7 Inspecting and Repairing Pins
62
Midplane Filler Strips
62
Inspecting Pins
63
Tools
63
To Inspect the Pins on the Rear Side of the Midplane
63
To Inspect the Pins on the Front Side of the Midplane
66
Repairing and Replacing Pins
69
Tools
69
To Remove Pins
69
To Remove a Pin with Needle-Nose Pliers
71
To Insert Pins
72
8 Installing Fabric Cards
74
Fabric Card Considerations
74
Inspecting Fabric Cards
75
To Inspect the Fabric Card Itrac Connectors
75
To Inspect the Fans
76
To Inspect the Retainers
77
Installing Fabric Cards into the Chassis
78
To Install the Midplane Stiffener
78
To Install the Fabric Cards
80
To Remove the Midplane Stiffener
81
Fabric Card Administrative Commands
83
To Enable Fabric Cards
83
To Disable Fabric Cards
83
To Enable Fabric Card IPMB Buses
84
To Disable Fabric Card IPMB Buses
84
To Enable Fabric Card Standby Power
84
To Disable Fabric Card Standby Power
84
To Fully Power on Fabric Cards
85
To Power down Fabric Cards to a Standby State
85
To Read Fabric Card FRUID Information
85
9 Installing Line Cards
88
Line Card Considerations
88
Inspecting Line Cards
89
To Inspect the Line Card Itrac Connectors
89
To Inspect the Ipass Connectors
90
To Inspect the Retainers
91
Installing Line Cards into the Chassis
92
To Install the Line Cards
92
Line Card Administrative Commands
93
To Disable Line Cards
94
To Enable Line Card IPMB Buses
94
To Disable Line Card IPMB Buses
94
To Enable Line Card Standby Power
94
To Disable Line Card Standby Power
95
To Fully Power on Line Cards
95
To Power down Line Cards to a Standby State
95
To Read Line Card FRUID Information
96
10 Powering on
98
Installing Power Supplies
98
To Install Power Supplies
98
Preparing Power Supplies
100
To Attach Power Cables
100
Power Supply Administrative Commands
101
To Power on Power Supplies
101
To Power down Power Supplies
102
To Verify Power Supply Status
102
Working with Cmcs
102
Powering on the Cmcs
103
To Cable Cmcs to the Management Console
103
To Access the CMC from the Serial Management Port
103
To Access the CMC from the Network Management Port
104
To Verify CMC Status
105
Powering on the Sun Datacenter Switch 3456
106
To Power on the Sun Datacenter Switch 3456
106
11 Cabling the Switch
108
Installing Cable Guides
108
To Install Cable Plates
108
To Remove Cable Plates
109
To Install Cable Trees
110
To Remove Cable Trees
111
To Install Cable Trays
112
To Remove Cable Trays
113
Cabling the Switch
113
Cable Cautions
114
To Attach Cables to the Sun Datacenter Switch 3456
114
To Remove Cables from the Sun Datacenter Switch 3456
117
To Check Link Status
118
Index
120
Advertisement
Sun Microsystems Datacenter Switch 3456 Service Manual (95 pages)
Brand:
Sun Microsystems
| Category:
Storage
| Size: 8 MB
Table of Contents
Table of Contents
3
Preface
7
Using UNIX Commands
7
Shell Prompts
8
Typographic Conventions
8
Related Documentation
8
Documentation, Support, and Training
9
Sun Welcomes Your Comments
9
Sun Datacenter Switch 3456 Overview
11
Switch Chassis
11
Power Supplies
12
Fan Units
13
Chassis Management Controllers
14
Fabric Cards
15
Line Cards
16
Chassis Service Procedures
19
Filler Panels
19
Removing the Filler Panel
19
Installing the Filler Panel
21
Midplane Connector Pins
23
Tools
23
Inspecting the Pins on the Rear Side of the Midplane
24
Inspecting the Pins on the Front Side of the Midplane
27
Removing Pins
30
Removing a Pin with Needle-Nose Pliers
31
Inserting Pins
32
Cable Management Hardware
33
Removing Cable Plates
33
Installing Cable Plates
33
Removing Cable Trees
34
Installing Cable Trees
35
Removing Cable Trays
37
Installing Cable Trays
37
Infiniband Cables
38
Cable Cautions
38
Removing Cables from the Sun Datacenter Switch 3456
39
Attaching Cables to the Sun Datacenter Switch 3456
40
Power Supply Service Procedures
45
Troubleshooting Power Supplies
46
Powering off Power Supplies
46
Section 3.1 "Troubleshooting Power Supplies
46
Section 3.2 "Powering off Power Supplies
46
Removing Power Supplies
47
Removing a Power Supply
47
Section 3.3 "Removing Power Supplies
47
Installing Power Supplies
49
Installing a Power Supply
49
Section 3.4 "Installing Power Supplies
49
Powering on Power Supplies
51
Section 3.5 "Powering on Power Supplies
51
Fan Service Procedures
53
Troubleshooting Fans
53
Removing Fans
53
Removing a Fan
53
Installing Fans
54
Installing a Fan
55
Chassis Management Controller Service Procedures
57
Troubleshooting Cmcs
58
Powering off Cmcs
58
Removing Cmcs
59
Removing a CMC
59
Installing Cmcs
60
Installing a CMC
60
Powering on Cmcs
62
Fabric Card Service Procedures
63
Fabric Card Considerations
63
Troubleshooting Fabric Cards
64
Section 6.2 "Troubleshooting Fabric Cards
64
Inspecting Fabric Cards
65
Inspecting the Fabric Card Itrac Connectors
65
Section 6.3 "Inspecting Fabric Cards
65
Inspecting the Fans
67
Inspecting the Retainers
67
Powering off Fabric Cards
68
Section 6.4 "Powering off Fabric Cards
68
Removing Fabric Cards
69
Removing a Fabric Card
69
Section 6.5 "Removing Fabric Cards
69
Installing Fabric Cards
70
Installing a Fabric Card
70
Section 6.6 "Installing Fabric Cards
70
Powering on Fabric Cards
72
Section 6.7 "Powering on Fabric Cards
72
Line Card Service Procedures
75
Line Card Considerations
75
Troubleshooting Line Cards
76
Section 7.2 "Troubleshooting Line Cards
76
Inspecting Line Cards
77
Inspecting the Line Card Itrac Connectors
77
Section 7.3 "Inspecting Line Cards
77
Inspecting the Line Card Ipass Connectors
79
Inspecting the Retainers
79
Powering off Line Cards
80
Section 7.4 "Powering off Line Cards
80
Removing Line Cards
81
Removing a Line Card
81
Section 7.5 "Removing Line Cards
81
Installing Line Cards
85
Installing a Line Card
85
Section 7.6 "Installing Line Cards
85
Powering on Line Cards
88
Section 7.7 "Powering on Line Cards
88
Advertisement
Related Products
Sun Microsystems Brocade SilkWorm 3200
Sun Microsystems Brocade SilkWorm 3250
Sun Microsystems Brocade SilkWorm 3850
Sun Microsystems 3400
Sun Microsystems Sun StorEdge Network Data Replicator 3.0
Sun Microsystems Enterprise 3500
Sun StorEdge 3910
Sun Microsystems StorEdge 3900SL
Sun Microsystems StorEdge 3511
Sun Microsystems StorEdge 3510 FC
Sun Microsystems Categories
Server
Storage
Desktop
Computer Hardware
Adapter
More Sun Microsystems Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL