5. Enable both IPMB buses for all fabric cards and line cards, type:
# enableAllIPMB
The enableAllIPMB script runs the enableipmb command for both the A and B
buses for each fabric card and line card.
6. Enable standby power for all fabric cards and line cards, type:
# enableAllStby
The enableAllStby script runs the enablestby command for each fabric card
and line card.
7. Bring each fabric card to full power, type:
# activate fc slot
where slot is 0 to 17.
8. Check fan operation, type:
# checkfans
If a fan's speed is too low or the fan has stopped, investigate why. See the Sun
Datacenter Switch 3456 Service Manual for further assistance.
9. Bring each line card to full power, type:
# activate lc slot
where slot is 0 to 23.
10. Again verify all installed components are recognized as installed, type:
# showpresent
If an installed component is not recognized, investigate why. See the Sun
Datacenter Switch 3456 Administration Guide and Sun Datacenter Switch 3456 Service
Manual for further assistance.
The Sun Datacenter Switch 3456 is now operational.
See the Sun Datacenter Switch 3456 Administration Guide for information about
administrative commands.