Mitsubishi Electric RD77MS2 User Manual page 126

Melsec iq-r simple motion module
Hide thumbs Also See for RD77MS2:
Table of Contents

Advertisement

• If the corresponding position is not found until the last point of the cam data, searches from the 0th point of the cam data.
• Searches until between the 127th point and the 128th point in order of the cam data between the 0th point and the 1st point
and between the 1st point and the 2nd point.
■Coordinate data format
(1) The range before the 1st point of cam data
When the 1st point of the cam data is larger than 0 and "[Cd.617] Cam position calculation: Cam axis current value per cycle
< the 1st point of cam data", the position corresponding to "[Cd.618] Cam position calculation: Cam axis feed current value" is
searched from the range before the 1st point of the cam data.
If the corresponding position is not found in the range of (1), searches in the range of (2). If the corresponding position is not
found in the range of (2) either, searches in the range of (3).
If the corresponding position is not found even though the range of (1) to (3) has been searched, the warning "Cam position
calculation cam axis 1 cycle current value calculation disable" (warning code: 0C64H) will occur in reciprocated cam pattern.
For the feed cam, calculates "[Cd.618] Cam position calculation: Cam axis feed current value" by the stroke difference and
searches again from the 0th point to the whole range. If the corresponding position is not found even though the search
process starts again, the warning "Cam position calculation cam axis 1 cycle current value calculation disable" (warning code:
0C64H) will occur.
Ex.
When "[Cd.617] Cam position calculation: Cam axis current value per cycle" is set before the 1st point of cam data
Search starting point
At the 0th point
(Cam reference position)
• Searches from the range of (1).
• If the corresponding position is not found in the range of (1), searches from the 1st point of the cam data in the range of (2).
(2) The range within the cam data
When "[Cd.617] Cam position calculation: Cam axis current value per cycle < the last point of cam data", the position
corresponding to "[Cd.618] Cam position calculation: Cam axis feed current value" is searched from the range of the cam
data.
When "the nth point of cam data  [Cd.617] Cam position calculation: Cam axis current value per cycle < the n + 1st point of
cam data", the position corresponding to "[Cd.618] Cam position calculation: Cam axis feed current value" is searched from
the nth point of cam data.
If "[Cd.617] Cam position calculation: Cam axis current value per cycle" is in the middle of the cam data and the
corresponding position is not found until the last point of the cam data, returns to the 1st point and searches until the search
starting point.
If the corresponding position is not found in the range of (2), searches in the range of (3).
If the corresponding position is not found even though the range of (2) and (3) has been searched, the warning "Cam position
calculation cam axis 1 cycle current value calculation disable" (warning code: 0C64H) will occur in reciprocated cam pattern.
For the feed cam, calculates "[Cd.618] Cam position calculation: Cam axis feed current value" by the stroke difference and
searches again from the 0th point to the whole range. If the corresponding position is not found even though the search
process starts again, the warning "Cam position calculation cam axis 1 cycle current value calculation disable" (warning code:
0C64H) will occur.
5 SYNCHRONOUS CONTROL INITIAL POSITION
124
5.5 Cam Position Calculation Function
1
At the 1st point
[Cd.617] Cam position calculation: Cam
axis current value per cycle
0
(1)
Cam axis length per cycle [Cam axis cycle units]
2
At the 2nd point
At the 3rd point
At the 4th point
(2)
3
Search order
At the 5th point
(3)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rd77ms4Rd77ms8Rd77ms16

Table of Contents