ELECTRICAL SYSTEM
TE 250 - 310 2012 I.E. / TE 250 - 310 2012 I.E. USA
TC 250 2012 - TC 250 2012 I.E. USA
TXC 250 - 310 2012 I.E. USA

• Connection of relays and fuses (TE-TXC)

12
13
RELAYS
14
Connect the cable marked "POW" to relay (12)
Connect the cable marked "FAN" to relay (13)
Connect the cable marked "DC" to relay (14) (TE only)
FUSES
15
Connect the cable marked "POW" to fuse (15)
Connect the cable marked "MAN" to fuse (16)
H00939
Connect the cable marked "FAN" (TXC) to fuse (17)
16
17
Connect the cable marked "DC+FAN" (TE) to fuse (17)

• Electric fan connection (TE-TXC)

Connect the electric fan connector (18).
18
H00940

• Injector connection (TE-TXC)

Connect the connector (19) to the throttle body.

• Ignition coil connection (TE-TXC)

Connect the ignition coil connector (20) as shown.