ELECTRICAL SYSTEM
TC 250 2012 - TC 250 2012 I.E. USA
TXC 250 - 310 2012 I.E. USA

• Securing the voltage regulator ground cable (9) (TE-TXC)

Secure the regulator ground cable to the right-hand screw of the injection coil.

• Securing the engine ground / chassis ground cables (10).

Electrical system ground
Secure the engine ground / chassis ground cable and the wiring harness ground
eye terminal to the coil retaining screw.

• Wiring connection to voltage regulator (TE-TXC)

Connect the connector (11) to the regulator. Pay attention to the routing of radia-
tor breather hose and throttle cables.