Mitsubishi Electric MR-J4-TM Instruction Manual page 571

Servo amplifier melservo-j4
Hide thumbs Also See for MR-J4-TM:
Table of Contents

Advertisement

APPENDIX
(3) Connector insertion
Insert the connector all the way straight until you hear or feel clicking. When removing the connector,
depress the lock part completely before pulling out. If the connector is pulled out without depressing the
lock part completely, the housing, contact and/or wires may be damaged.
(4) Compatible wire
Compatible wire size is listed below.
(5) Others
(a) Fix a wire tie at least distance of "A" × 1.5 away from the end of the connector.
(b) Be sure that wires are not pulled excessively when the connector is inserted.
App. 5.8.4 Wiring FG
Wire size
2
mm
0.22
0.34
0.50
Wire range
Single wire: φ 0.4 mm to 1.2 mm (AWG 26 to AWG 16)
Stranded wire: 0.2 mm
wire φ 0.18 mm or more
Bottom face
Lead wire
App. - 34
AWG
24
22
20
A × 1.5 or more
2
to 1.25 mm
2
(AWG 24 to AWG 16),

Advertisement

Table of Contents
loading

Table of Contents