Mitsubishi Electric MR-J4-TM Instruction Manual page 581

Servo amplifier melservo-j4
Hide thumbs Also See for MR-J4-TM:
Table of Contents

Advertisement

APPENDIX
(2) Setting
The servo amplifier is factory-set to output the servo motor speed to MO1 (Analog monitor 1) and the
torque to MO2 (Analog monitor 2). The setting can be changed as listed below by setting the [Pr. PC09]
and [Pr. PC10] value.
Refer to (3) for the detection point.
Setting
Output item
value
00
Servo motor speed
02
Servo motor speed
04
Current command
06
Servo motor-side droop
pulses
(Note 1, 3, 5, 6)
(±10 V/100 pulses)
08
Servo motor-side droop
pulses
(Note 1, 3, 5, 6)
(±10 V/10000 pulses)
POINT
When you use a linear servo motor, replace the following left words to the right
words.
CCW direction
CW direction
Torque
Description
CCW direction
8 [V]
Maximum speed
0
Maximum speed
-8 [V]
CW direction
8 [V]
CW direction
CCW direction
0
Maximum speed
Maximum speed
CCW direction
8 [V]
Maximum current command
(Maximum torque command)
0
Maximum current command
(Maximum torque command)
-8 [V]
CW direction
CCW direction
10 [V]
100 [pulse]
0
100 [pulse]
-10 [V]
CW direction
CCW direction
10 [V]
10000 [pulse]
0
10000 [pulse]
-10 [V]
CW direction
App. - 44
→ Positive direction
→ Negative direction
→ Thrust
Setting
Output item
value
01
Torque/Thrust
03
Torque/Thrust
05
Speed command
(Note 3)
07
Servo motor-side droop
pulses
(Note 1, 3, 5, 6)
(±10 V/1000 pulses)
09
Servo motor-side droop
pulses
(Note 1, 3, 5, 6)
(±10 V/100000 pulses)
Description
Power running in
CCW direction
8 [V]
Maximum torque
0
Maximum torque
-8 [V]
Power running in
CW direction
Power running in
Power running in
CW direction
CCW direction
8 [V]
0
Maximum torque
Maximum torque
CCW direction
8 [V]
Maximum speed
0
Maximum speed
-8 [V]
CW direction
CCW direction
10 [V]
1000 [pulse]
0
1000 [pulse]
-10 [V]
CW direction
CCW direction
10 [V]
100000 [pulse]
0
100000 [pulse]
-10 [V]
CW direction

Advertisement

Table of Contents
loading

Table of Contents