4. STARTUP

4.3.2 Scrolling display

Axis number will be displayed in hexadecimal. For 100h or more, last two digits will be displayed.
(1) Normal display
(a) For EtherCAT
When there is no alarm, the axis No. and blank are displayed in rotation.
(b) For EtherNet/IP
When there is no alarm, the IP address is displayed.
(2) Alarm display
When an alarm occurs, the alarm number (two digits) and the alarm detail (one digit) are displayed
following the status display. For example, the following shows when [AL. 32 Overcurrent] is occurring.
After 1.6 s
Status
Blank
After 0.2 s
Status
Axis No.
(1 digit)
(2 digits)
"b"
: Indicates ready-off and servo-off status.
"C"
: Indicates ready-on and servo-off status.
"d"
: Indicates ready-on and servo-on status.
Status
IP address
(1 digit)
(2 digits)
"b"
: Indicates ready-off and servo-off status.
"C"
: Indicates ready-on and servo-off status.
"d"
: Indicates ready-on and servo-on status.
After 0.8 s
After 0.8 s
Status
Alarm No.
After 0.2 s
Status
Axis No.
Alarm No.
(1 digit)
(2 digits)
(2 digits)
"n": Indicates that an alarm is occurring.
4 - 9
Blank
Alarm detail
(1 digit)