Mitsubishi Electric MR-J4-TM Instruction Manual page 285

Servo amplifier melservo-j4
Hide thumbs Also See for MR-J4-TM:
Table of Contents

Advertisement

8. TROUBLESHOOTING
No.
32
33
35
37
3A
42
45
46
47
50
51
Detail
Name
No.
32.1
32.2
Overcurrent
32.3
32.4
Overvoltage
33.1
Command frequency error
35.1
37.1
Parameter error
37.2
Inrush current suppression
3A.1
circuit error
42.1
Servo control error
(for linear servo motor and
42.2
direct drive motor)
42.3
42.8
Fully closed loop control
error (during fully closed
42.9
loop control)
42.A
45.1
Main circuit device
overheat
45.2
46.1
46.2
46.3
Servo motor overheat
46.4
46.5
46.6
47.1
Cooling fan error
47.2
50.1
50.2
50.3
Overload 1
50.4
50.5
50.6
51.1
Overload 2
51.2
Detail name
Overcurrent detected at hardware detection
circuit (during operation)
Overcurrent detected at software detection
function (during operation)
Overcurrent detected at hardware detection
circuit (during a stop)
Overcurrent detected at software detection
function (during a stop)
Main circuit voltage error
Command frequency error
Parameter setting range error
Parameter combination error
Inrush current suppression circuit error
Servo control error by position deviation
Servo control error by speed deviation
Servo control error by torque/thrust deviation
Fully closed loop control error by position
deviation
Fully closed loop control error by speed
deviation
Fully closed loop control error by position
deviation during command stop
Main circuit device overheat error 1
Main circuit device overheat error 2
Abnormal temperature of servo motor 1
Abnormal temperature of servo motor 2
Thermistor disconnected error
Thermistor circuit error
Abnormal temperature of servo motor 3
Abnormal temperature of servo motor 4
Cooling fan stop error
Cooling fan speed reduction error
Thermal overload error 1 during operation
Thermal overload error 2 during operation
Thermal overload error 4 during operation
Thermal overload error 1 during a stop
Thermal overload error 2 during a stop
Thermal overload error 4 during a stop
Thermal overload error 3 during operation
Thermal overload error 3 during a stop
8 - 4
Alarm deactivation
Stop
method
(Note 4,
5)
DB
DB
DB
DB
EDB
SD
DB
DB
EDB
EDB
(Note 3) (Note 3)
EDB
(Note 3) (Note 3)
EDB
(Note 3) (Note 3)
EDB
(Note 3) (Note 3)
EDB
(Note 3) (Note 3)
EDB
(Note 3) (Note 3)
SD
(Note 1) (Note 1) (Note 1)
SD
(Note 1) (Note 1) (Note 1)
SD
(Note 1) (Note 1) (Note 1)
SD
(Note 1) (Note 1) (Note 1)
SD
(Note 1) (Note 1) (Note 1)
SD
(Note 1) (Note 1) (Note 1)
DB
(Note 1) (Note 1) (Note 1)
DB
(Note 1) (Note 1) (Note 1)
SD
SD
SD
(Note 1) (Note 1) (Note 1)
SD
(Note 1) (Note 1) (Note 1)
SD
(Note 1) (Note 1) (Note 1)
SD
(Note 1) (Note 1) (Note 1)
SD
(Note 1) (Note 1) (Note 1)
SD
(Note 1) (Note 1) (Note 1)
DB
(Note 1) (Note 1) (Note 1)
DB
(Note 1) (Note 1) (Note 1)

Advertisement

Table of Contents
loading

Table of Contents