8. TROUBLESHOOTING

8.4 Remedies

CAUTION
If [AL. E6] or [AL. E9] occurs, the amplifier will be the servo-off status. If any other warning occurs, operation
can be continued but an alarm may occur and proper operation may not be performed.
Refer to this section and remedies for warnings of [GF] and [Others] in the MELSERVO-J4 Servo Amplifier
Instruction Manual (Troubleshooting) to remove the cause of a warning. Use MR Configurator2 to refer to the
cause of warning occurrence.
If [AL. E3 Absolute position counter warning] occurs, always make the home
position setting again. Otherwise, it may cause an unexpected operation.
POINT
This section explains remedies for warnings exclusively for the MR-J4-_TM_.
For remedies for any other warnings, refer to [GF] and [Others] in the
MELSERVO-J4 Servo Amplifier Instruction Manual (Troubleshooting).
When any of the following warnings occurs, do not cycle the power of the servo
amplifier repeatedly to restart. Doing so will cause a malfunction of the servo
amplifier and servo motor. If the power of the servo amplifier is switched off/on
during the warnings, allow more than 30 minutes for cooling before resuming
operation.
[AL. 91 Servo amplifier overheat warning]
[AL. E0 Excessive regeneration warning]
[AL. E1 Overload warning 1]
[AL. E2 Servo motor overheat warning]
[AL. EC Overload warning 2]
Warnings (except [AL. F0 Tough drive warning]) are not recorded in the alarm
history.