Mitsubishi Electric MR-J4-TM Instruction Manual page 540

Servo amplifier melservo-j4
Hide thumbs Also See for MR-J4-TM:
Table of Contents

Advertisement

APPENDIX
App. 1.3 Selection example of wires
The following diagram shows the wires used for wiring. Use the wires given in this section or equivalent.
(1) Example of selecting the wire sizes
Use the 600 V grade heat-resistant polyvinyl chloride insulated wire (HIV wire) for wiring. The following
shows the wire size selection example.
(2) Selection example of crimp terminals
POINT
Selection conditions of wire size are as follows.
Construction condition: Single wire set in midair
Wiring length: 30 m or shorter
Table app. 1 Wire size selection example (HIV wire)
Servo amplifier
MR-J4-10TM
MR-J4-20TM
MR-J4-40TM
MR-J4-60TM
MR-J4-70TM
MR-J4-100TM
MR-J4-200TM
MR-J4-350TM
MR-J4-500TM (Note 2)
MR-J4-700TM (Note 2)
MR-J4-11KTM (Note 2)
MR-J4-15KTM (Note 2)
MR-J4-22KTM (Note 2)
Note 1. Alphabets in the table indicate crimping tools. For crimp terminals and applicable
tools, refer to (2) in this section.
2. To connect these models to a terminal block, be sure to use the screws that come
with the terminal block.
Symbol
(Note 2)
Crimp terminal
a
FVD5.5-4
b (Note 1) 8-4NS
c
FVD2-4
d
FVD2-M3
e
FVD14-6
f
FVD22-6
g
FVD38-8
Note 1. Coat the crimping part with an insulation tube.
2. Some crimp terminals may not be mounted depending on their sizes. Make sure to use the
recommended ones or equivalent ones.
App. - 3
Wire [mm
L1/L2/L3/N-/
2 (AWG 14)
3.5 (AWG 12)
5.5 (AWG 10): a
8 (AWG 8): b
14 (AWG 6): e
22 (AWG 4): f
38 (AWG 2): g
Servo amplifier-side crimp terminal
Applicable tool
Body
Head
YNT-1210S
YHT-8S
YNT-1614
YF-1
YNE-38
YF-1
YNE-38
YF-1
YNE-38
2
] (Note 1)
L11/L21
1.25 to 2
(AWG 16 to 14)
1.25 (AWG 16): a
2 (AWG 14): d
1.25 (AWG 16): c
2 (AWG 14): c
Manufacturer
Dice
DH-122
JST
DH-112
DH-123
DH-113
DH-124
DH-114

Advertisement