3. SIGNALS AND WIRING
(d) MR-J4-10TM1 to MR-J4-40TM1
Connector
Receptacle assembly
CNP1
06JFAT-SAXGDK-H7.5
CNP2
05JFAT-SAXGDK-H5.0
CNP3
03JFAT-SAXGDK-H7.5
(2) Cable connection procedure
(a) Fabrication on cable insulator
Refer to table 3.1 to 3.4 for stripped length of cable insulator. The appropriate stripped length of
cables depends on their type, etc. Set the length considering their status.
Twist strands lightly and straighten them as follows.
Servo amplifier
CNP1
CNP2
CNP3
Table 3.4 Connector and applicable wire
Applicable wire
Size
AWG 18 to 14
Insulator
Core
Stripped length
Loose and bent strands
3 - 21
Stripped
length [mm]
Insulator OD
39 mm or shorter
9
Twist and straighten
the strands.
Manufa
Open tool
cturer
J-FAT-OT (N)
or
JST
J-FAT-OT