11. OPTIONS AND PERIPHERAL EQUIPMENT
(b) DBU-11K-4/DBU-22K-4
2-φ7 mounting hole
51
73.75
7
25
150
25
200
15
15
170
Terminal block
TE1
a
b
13
Screw: M3.5
Tightening torque: 0.8 [N•m]
External dynamic brake
DBU-11K-4
5.5 (AWG 10)
DBU-22K-4
5.5 (AWG 10)
Note. Selection conditions of wire size are as follows.
Wire type: 600 V grade heat-resistant polyvinyl chloride insulated wire (HIV wire)
Construction condition: Single wire set in midair
11 - 101
TE2
U
V
14
Screw: M4
Tightening torque: 1.2 [N•m]
2
(Note) Connection wire [mm
U/V/W
Except U/V/W
2 (AWG 14)
2 (AWG 14)
[Unit: mm]
2.3
195
15
210
Mass: 6.7 [kg]