Explanation Of Power Supply System - Mitsubishi Electric MR-J4-TM Instruction Manual

Servo amplifier melservo-j4
Hide thumbs Also See for MR-J4-TM:
Table of Contents

Advertisement

3. SIGNALS AND WIRING

3.3 Explanation of power supply system

3.3.1 Signal explanations
Connection target
Symbol
(application)
Main circuit power
L1/L2/L3
supply
Power factor
P3/P4
improving DC reactor
P+/C/D
Regenerative option
POINT
For the layout of connector and terminal block, refer to chapter 9 DIMENSIONS.
When using the servo amplifier with the DC power supply input, refer to app. 1.
Supply the following power to L1, L2, and L3. For 1-phase 200 V AC to 240 V AC, connect the
power supply to L1 and L3. Leave L2 open.
Servo amplifier
Power
3-phase 200 V AC to
240 V AC, 50 Hz/60 Hz
1-phase 200 V AC to
240 V AC, 50 Hz/60 Hz
3-phase 380 V AC to
480 V AC, 50 Hz/60 Hz
1-phase 100 V AC to
120 V AC, 50 Hz/60 Hz
When not using the power factor improving DC reactor, connect P3 and P4. (factory-wired)
When using the power factor improving DC reactor, disconnect P3 and P4, and connect the
power factor improving DC reactor to P3 and P4. Additionally, the power factor improving DC
reactor cannot be used for the 100 V class servo amplifiers.
Refer to section 11.11 for details.
(1) 200 V class/100 V class
1) MR-J4-500TM or less and MR-J4-40TM1 or less
When using a servo amplifier built-in regenerative resistor, connect P+ and D. (factory-
wired)
When using a regenerative option, disconnect P+ and D, and connect the regenerative
option to P+ and C.
2) MR-J4-700TM to MR-J4-22KTM
MR-J4-700TM to MR-J4-22KTM do not have D.
When using a servo amplifier built-in regenerative resistor, connect P+ and C. (factory-
wired)
When using a regenerative option, disconnect wires of P+ and C for the built-in
regenerative resistor. And then connect wires of the regenerative option to P+ and C.
(2) 400 V class
1) MR-J4-350TM4 or less
When using a servo amplifier built-in regenerative resistor, connect P+ and D. (factory-
wired)
When using a regenerative option, disconnect P+ and D, and connect the regenerative
option to P+ and C.
2) MR-J4-500TM4 to MR-J4-22KTM4
MR-J4-500TM4 to MR-J4-22KTM4 do not have D.
When using a servo amplifier built-in regenerative resistor, connect P+ and C. (factory-
wired)
When using a regenerative option, disconnect wires of P+ and C for the built-in
regenerative resistor. And then connect wires of the regenerative option to P+ and C.
Refer to section 11.2 for details.
Description
MR-J4-10TM
MR-J4-350TM
to
to
MR-J4-200TM
MR-J4-22KTM
L1/L2/L3
L1/L3
3 - 17
MR-J4-60TM4
MR-J4-10TM1
to
to
MR-J4-22KTM4
MR-J4-40TM1
L1/L2/L3
L1/L2