Fault Trace Contents - YASKAWA T1000V Technical Manual

Ac drive for textile applications
Table of Contents

Advertisement

C.10 MEMOBUS/Modbus Data Table

◆ Fault Trace Contents

The table below shows the fault codes that can be read out by MEMOBUS/Modbus commands from the U2-
monitor parameters.
Note: Uv1 and Uv2 faults are not saved to the fault history.
Fault Code
0002H
Undervoltage (Uv1)
0003H
Control Power Supply Undervoltage (Uv2)
0004H
Soft Charge Circuit Fault (Uv3)
0006H
Ground Fault (GF)
0007H
Overcurrent (oC)
0008H
Overvoltage (ov)
0009H
Heatsink Overheat (oH)
000AH
Heatsink Overheat (oH1)
000BH
Motor Overload (oL1)
000CH
Drive Overload (oL2)
000DH
Overtorque Detection 1 (oL3)
000EH
Overtorque Detection 2 (oL4)
000FH
Dynamic Braking Transistor (rr)
0010H
Braking Resistor Overheat (rH)
0011H
External Fault at input terminal S3 (EF3)
0012H
External Fault at input terminal S4 (EF4)
0013H
External Fault at input terminal S5 (EF5)
0014H
External Fault at input terminal S6 (EF6)
0018H
Overspeed (oS)
0019H
Excessive Speed Deviation (dEv)
001AH
PG Disconnect (PGo)
001BH
Input Phase Loss (PF)
001CH
Output Phase Loss (LF)
001DH
Motor Overheat (PTC input) (oH3)
001EH
Digital Operator Connection (oPr)
001FH
EEPROM Write Error (Err)
0020H
Motor Overheat (PTC input) (oH4)
0021H
MEMOBUS/Modbus Communication Error (CE)
0022H
Option Communication Error (bUS)
0025H
Control fault (CF)
0027H
Option Card External Fault (EF0)
0028H
PID Feedback Loss (FbL)
0029H
Undertorque Detection 1 (UL3)
402
Table C.4 Fault Trace/History Register Contents
Fault Name
YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual
Fault Code
002AH
Undertorque Detection 2 (UL4)
0030H
Hardware Fault (including oFx)
0036H
Output Current Imbalance (LF2)
0037H
Pullout Detection (Sto)
0038H
PG Disconnected (PGo)
003BH
Too many speed search restarts (SEr)
0041H
PID Feedback Loss (FbH)
0042H
External Fault 1, input terminal S1 (EF1)
0043H
External Fault 2, input terminal S2 (EF2)
0046H
Current Offset Fault (CoF)
0083H
A/D Conversion Error (CPF02)
0084H
PWM Data Fault (CPF03)
Drive specification mismatch during Terminal Board
0087H
or Control Board replacement (CPF06)
0088H
Terminal Board Communication Fault (CPF07)
0089H
EEPROM Serial Communication Fault (CPF08)
008CH
RAM fault (CPF11)
008DH
Flash memory circuit exception (CPF12)
008EH
Watchdog circuit exception (CPF13)
008FH
Control Circuit Fault (CPF14)
0091H
Clock Fault (CPF16)
0092H
Timing Fault (CPF17)
0093H
Control Circuit Fault (CPF18)
0094H
Control Circuit Fault (CPF19)
0095H
Hardware fault at power up (CPF20)
0096H
Hardware fault at communication start up (CPF21)
0097H
A/D Conversion Fault (CPF22)
0098H
PWM Feedback Fault (CPF23)
0099H
Drive capacity signal fault (CPF24)
0101H
Option compatibility error (oFA00)
0102H
Option not properly connected (oFA01)
0104H
Option Self-diagnostics Error (oFA03)
0105H
Option Flash Write Mode Error (oFA04)
Fault Name