Setting 2: Open Loop Vector
• For general, variable-speed applications.
• For applications requiring precise speed control, quick response, and higher torque at low speeds.
Setting 5: PM Open Loop Vector
For operating SPM, IPM, and various permanent magnet motors. Takes advantage of Energy Saving features when
operating with derated torque.
A1-03: Initialize Parameters
Resets parameter settings back to their original default values. After the initialization the parameter automatically returns
to 0.
No.
A1-03
Setting 0: No Initialize
Setting 1110: User Initialize
The modified drive parameters are returned to the values selected as user settings. User settings are stored when
parameter o2-03 = "1: Set Defaults".
Note: A "user-initialization" resets all parameters to a user-defined set of default values that were previously saved to the drive. To
clear the user-defined default values, set parameter o2-03 to "2".
Setting 2220: 2-Wire Initialization
Resets all parameters back to their original default settings with digital inputs S1 and S2 configured as forward run and
reverse run, respectively. A 2-wire sequence assigns functions to input terminals S1 and S2. Refer to page 181 for more
information.
Setting 3330: 3-Wire Initialization
The drive parameters are returned to factory default values with digital inputs S1, S2, and S5 configured as run, stop, and
forward/reverse respectively. A 3-wire sequence assigns functions to terminals S1, S2, and S5. Refer to page 175 for
more information.
Setting 5550: oPE04 Reset
If parameters on a certain drive have been edited and then a different terminal block is installed with different settings
saved in its built-in memory, an oPE04 error will appear on the display. To use the parameter settings saved to the
terminal block memory, set A1-02 to "5550".
Notes on Parameter Initialization
The parameters shown in
fault history will not be reset when the drive is initialized by A1-03 = 2220 or 3330. The control mode in A1-02 is not
reset when A1-03 is set to 2220 or 3330.
No.
A1-00
A1-02
E5-01
E5-02
E5-03
E5-04
E5-05
E5-06
E5-07
E5-09
E5-24
o2-04
L8-35
YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual
Parameter Name
Initialize Parameters
Table 5.1
will not be reset when the drive is initialized by setting A1-03 = 2220 or 3330. The
Table 5.1 Parameters not Changed by Drive Initialization
0, 1110, 2220, 3330, 5550
Parameter Name
Language Selection
Control Method Selection
PM Motor Code Selection
Motor Rated Capacity (for PM motors)
Motor Rated Current (for PM motors)
Motor Poles (for PM motors)
Motor Armature Resistance (for PM motors)
Motor d Axis Inductance (for PM motors)
Motor q Axis Inductance (for PM motors)
Motor Induction Voltage Constant 1 (for PM motors)
Motor Induction Voltage Constant 2 (for PM motors)
Drive/kVA Selection
Installation Selection
5.1 A: Initialization
Setting Range
Default
0
5
103