◆ L: Protection Function

L parameters provide protection to the drive and motor, such as: control during momentary power loss, Stall Prevention,
frequency detection, fault restarts, overtorque detection, torque limits and other types of hardware protection.
No.
Name
Motor Overload Protection
L1-01
Selection
Motor Overload Protection
L1-02
Time
Motor Overheat Alarm
L1-03
Operation Selection (PTC
input)
YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual
Description
Sets the level of the value selected in H6-01 when 0 Hz is
input.
Sets the pulse train input filter time constant.
Select the pulse train monitor output function (value of the
-
part of U -
).
Refer to U: Operation Status Monitors on page 358
the list of U monitors.
Example: To select U5-01, set "501. "When not using this
parameter or when using in the through mode, set "000".
Sets the terminal MP output signal frequency when the
monitor value is 100%. Set H6-06 to "102" and H6-07 to
"0", to make the pulse train monitor output equal to the
output frequency.
Sets the minimum frequency for the pulse train input to be
detected. Enabled when H6-01 = 0, 1, or 2.
Description
L1: Motor Protection
Use L1 parameters to configure motor protective functions.
Sets the motor thermal overload protection (oL1) based on
the cooling capacity of the motor.
0: Disabled
1: Standard Fan Cooled (speed range < 10:1)
2: Standard Blower Cooled (speed range ≥ 10:1)
3: Vector Motor (speed range 100:1)
4: PM motor with variable torque
NOTICE: When using a single drive to operate multiple
motors, set L1-01 to 0 and ensure each motor has a thermal
relay installed.
Sets the motor thermal overload protection (oL1) time.
A larger L1-02 time will increase the time for an oL1 fault
to occur.
This parameter does not typically require adjustment.
Should be set in accordance with the overload tolerance of
the motor.
Sets operation when the motor temperature analog input
(H3-02 and H3-10 = E) exceeds the oH3 alarm level (PTC
input level: Tr-5°C).
0: Ramp to Stop
1: Coast to Stop
2: Fast-stop using C1-09
3: Alarm Only ("oH3" will flash)
B.3 Parameter Table
Control
Mode
Range
Def.
V/f OL
V
-100.0 to
0.0% A A A
+100.0
0.00 to
0.10 s A A A
2.00
000, 031,
for
101, 102,
102
A A A
105, 116,
501, 502
1440
0 to 32000
A A A
Hz
0.1 to
0.5
A A A
1000.0
Hz
Control
Mode
Range
Def.
OL
V/f
V
1
0 to 4
S
S
<2>
1.0
0.1 to 5.0
A A A
min
0 to 3
3
A A A
Addr.
Pg.
Hex
P
M
42F
184
430
184
431
184
432
184
43F
184
Addr.
Pg.
Hex
P
M
S
480
185
481
187
482
188
B
343