H: Terminal Functions

H parameters are used to assign functions to the external terminals.

◆ H1: Multi-Function Digital Inputs

H1-01 to H1-06: Functions for Terminals S1 to S6
These parameters assign functions to the multi-function digital inputs. The settings 0 to 7E determine function for each
terminal and are explained below.
Note: If not using an input terminal or if using the through-mode, set that terminal to "F".
No.
H1-01
Multi-Function Digital Input S1 Terminal Function Selection
H1-02
Multi-Function Digital Input S2 Terminal Function Selection
H1-03
Multi-Function Digital Input S3 Terminal Function Selection
H1-04
Multi-Function Digital Input S4 Terminal Function Selection
H1-05
Multi-Function Digital Input S5 Terminal Function Selection
H1-06
Multi-Function Digital Input S6 Terminal Function Selection
<1> Number appearing in parenthesis is the default value after performing a 3-Wire initialization.
Setting
0
3-Wire Sequence
1
LOCAL/REMOTE Selection
2
External Reference 1/2
3
Multi-Step Speed Reference 1
4
Multi-Step Speed Reference 2
5
Multi-Step Speed Reference 3
6
Jog Reference Selection
7
Accel/Decel Time 1
8
Baseblock Command (N.O.)
9
Baseblock Command (N.C.)
A
Accel/Decel Ramp Hold
B
Drive Overheat Alarm (oH2)
C
Terminal A1/A2 Enable/Disable
F
Not used/Through Mode
10
Up Command
11
Down Command
12
Forward Jog
13
Reverse Jog
14
Fault Reset
15
Fast-Stop (N.O.)
16
Motor 2 Selection
17
Fast-stop (N.C.)
18
Timer Function Input
19
PID Disable
1A
Accel/Decel Time Selection 2
1B
Program Lockout
<1> This setting is valid from software versions 6000 or later.
YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual
Parameter Name
Table 5.16 Digital Multi-Function Input Settings
Function
Setting
Range
1 to 7E
40 (F): Forward Run Command (2-wire sequence)
1 to 7E
41 (F): Reverse Run Command (2-wire sequence)
0 to 7E
24: External Fault
0 to 7E
14: Fault Reset
0 to 7E
3 (0)
: Multi-Step Speed Reference 1
<1>
0 to 7E
4 (3)
: Multi-Step Speed Reference 2
<1>
Page
Setting
160
20 to 2F
External Fault
160
30
PID Integral Reset
161
31
PID Integral Hold
34
PID Soft Starter Cancel
161
35
PID Input Level Selection
40
Forward Run/Stop (2-wire sequence)
161
41
Reverse Run/Stop (2-wire sequence)
161
42
Run/Stop (2-Wire sequence 2)
43
FWD/REV (2-Wire sequence 2)
161
44
Offset Frequency 1 Addition
161
45
Offset Frequency 2 Addition
161
46
Offset Frequency 3 Addition
162
47
Node Setup
<1>
162
50
Disturb Function Cancel
51
Synchronous Accel/Decel
162
53
Energy Saving On/Off
59
DC Injection Braking 1
163
60
DC Injection Braking 2
163
61
External Speed Search Command 1
163
62
External Speed Search command 2
164
65
KEB 1 (N.C.)
163
66
KEB 1 (N.O.)
164
67
Communications Test Mode
164
7C
Short-Circuit Braking (N.O.)
164
7D
Short-Circuit Braking (N.C.)
Forward/Reverse Detection (V/f Control with
164
7E
Simple PG Feedback)

5.7 H: Terminal Functions

Default
Function
Page
165
165
165
165
165
165
166
166
166
166
166
166
166
167
167
5
167
167
167
167
168
159

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents