YASKAWA T1000V Technical Manual page 205

Ac drive for textile applications
Table of Contents

Advertisement

L8-51: STo Level
Sets the STo detection level as a percentage of the motor rated current. If set to zero, then the drive will automatically
calculate an appropriate detection level. This setting is rarely needs to be changed.
Note: This parameter is valid from software version 6002 or later.
No.
L8-51
L8-54: STo Bias Detection Selection
Enables and disables a deviation detection of STo detection. This setting is rarely needs to be changed.
Note: This parameter is valid from software version 6002 or later.
No.
L8-54
Setting 0: No deviation detection
Setting 1: Deviation detection is enabled
YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual
Name
STo Level
Name
STo Bias Detection Selection
5.8 L: Protection Functions
Setting Range
0.0 to 150.0%
Setting Range
0, 1
Default
0.0%
Default
1
5