n8-76: Id Filter Time (for PM OLV)
Sets Id filter time for PM OLV control mode.
Note: This parameter is valid from software version 6002 or later.
No.
n8-76
n8-77: Id Load Slp End (for PM OLV)
Sets Id current level for high loads.
Note: This parameter is valid from software version 6002 or later.
No.
n8-77
<1> Setting range is determined as follows: (n8-50 + 0.1%) to 250.0%.
n8-78: Id Medium Value (for PM OLV)
Sets Id current level for medium loads.
Note: This parameter is valid from software version 6002 or later.
No.
n8-78
n8-87: Output Voltage Limit Selection
Sets how the output voltage limit should be used. This setting is rarely needs to be changed.
Note: This parameter is valid from software version 6002 or later.
No.
n8-87
0: Feedback type
1: Feed Forward type
n8-88: Output Voltage Limit Switch Current Level
Sets the current level to switch the output voltage limit sequence. Set as a percentage of the motor rated current (E5-03).
This setting is rarely needs to be changed.
Note: This parameter is valid from software version 6002 or later.
No.
n8-88
n8-89: Output Voltage Limit Switch Hysteresis Width
Sets hysteresis used for the current level that switches the output voltage limit sequence. Set as a percentage of the motor
rated current (E5-03). This setting is rarely needs to be changed.
Note: This parameter is valid from software version 6002 or later.
No.
n8-89
Output Voltage Limit Switch Hysteresis Width
n8-90: Output Voltage Limit Switch Speed
Sets the speed level for switching the output voltage limit sequence. Set as a percentage of the maximum output
frequency (E1-04). This setting is rarely needs to be changed.
Note: This parameter is valid from software version 6002 or later.
No.
n8-90
YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual
Name
Id Filter Time
Name
Id Load Slp End
Name
Id Medium Value
Name
Output Voltage Limit Selection
Name
Output Voltage Limit Switch Current Level
Name
Name
Output Voltage Limit Switch Speed
5.9 n: Special Adjustments
Setting Range
0 to 5000 ms
Setting Range
<1>
Setting Range
-200.0 to 200.0%
Setting Range
0, 1
Setting Range
0 to 400%
Setting Range
0 to n8-88
Setting Range
0 to 200%
Default
200 ms
Default
90.0%
Default
0.0%
Default
0
Default
400%
5
Default
3%
Default
200%