YASKAWA T1000V Technical Manual page 61

Ac drive for textile applications
Table of Contents

Advertisement

To disconnect control wires from the terminals use the procedure described in the following figure. Grasp the wire where
it enters the terminal with a pair of pliers, then use a slotted-tip screwdriver to release the terminal and pull the wire out.
If it fits tightly, i.e., if ferrules are used, turn the wire 45 degrees and gently remove it. Use this procedure to remove the
wire jumper between terminals HC and H1 that is installed at shipping.
Figure 3.15
Figure 3.16
A – Drive side
B – Connect shield to ground terminal of
drive.
C – Insulation
When setting the frequency by analog reference from an external potentiometer, use shielded twisted-pair wires and
ground the shield of twisted-pair wires to the ground terminal of the drive.
NOTICE: The analog signal lines between the drive and the operator station or peripheral equipment should not exceed 50 meters
when using an analog signal from a remote source to supply the frequency reference. Failure to comply could result in poor system
performance.
Figure 3.17
A – Drive
B – Ground terminal (shield connection)
C – (RP) Pulse train (maximum 32 kHz)
D – (+V) Frequency setting power source
+10.5 Vdc maximum 20 mA
Figure 3.17 Wiring the Frequency Reference to the Control Circuit Terminals (External Reference)
YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual
Push down to open
the terminal
Control Wires
Terminal Board
Figure 3.15 Removing Wires from the Terminal Board
F
A
B
Figure 3.16 Preparing the Ends of Shielded Cables
2 k
G
Turn the wire ~ 45
and pull it out of the
terminal.
Use a screwdriver with a blade
width of max 2.5 mm and a
thickness of max 0.4 mm
C
D
E
D – Control device side
E – Shield sheath (Insulate with tape)
F – Shield
A
B
C
RP
D
+V
E
A1
F
A2
AC
E – (A1) Main speed frequency reference
0 to +10 Vdc (20 kΩ)
F – (A2) Multi-function analog input 0 to
+10 Vdc (20 kΩ) or 4 to 20 mA (250 Ω)/
0 to 20 mA (250 Ω)
G – Frequency setting potentiometer
3.7 Control Circuit Wiring
3
61

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents