E: Motor Parameters - YASKAWA T1000V Technical Manual

Ac drive for textile applications
Table of Contents

Advertisement

B.3 Parameter Table

◆ E: Motor Parameters

No.
Name
E1-01
Input Voltage
Setting
<17>
V/f Pattern
E1-03
Selection
Maximum Output
E1-04
Frequency
E1-05
Maximum Voltage
<17>
E1-06
Base Frequency
Middle Output
E1-07
Frequency
E1-08
Middle Output
Frequency Voltage
<17>
Minimum Output
E1-09
Frequency
E1-10
Minimum Output
Frequency Voltage
<17>
E1-11
Middle Output
Frequency 2
<19>
Middle Output
E1-12
Frequency Voltage
<17> <19>
2
E1-13
Base Voltage
<17>
E2-01
Motor Rated
Current
<34>
E2-02
Motor Rated Slip
Motor No-Load
E2-03
Current
Number of Motor
E2-04
Poles
Motor Line-to-Line
E2-05
Resistance
Motor Leakage
E2-06
Inductance
Motor Iron-Core
E2-07
Saturation
Coefficient 1
Motor Iron-Core
E2-08
Saturation
Coefficient 2
330
Description
E1: V/f Pattern for Motor 1
Use E1 parameters to set V/f characteristics for the motor.
This parameter must be set to the power supply voltage.
WARNING! Drive input voltage (not motor voltage)
must be set in E1-01 for the protective features of the
drive to function properly. failure to do so may result in
equipment damage and/or death or personal injury.
F: Custom V/f. E1-04 through E1-13 settings define the
V/f pattern.
To set linear V/f characteristics, set the same values for
E1-07 and E1-09. In this case, the setting for E1-08 will
be disregarded. When E1-13 = 0.0 V, then the drive uses
the value set to E1-05 to control the voltage level. Ensure
that the four frequencies are set according to these rules:
E1-04 ≥ E1-06> E1-07 ≥ E1-09
VACrms Out(V)
E1-05
E1-12
E1-13
E1-08
E1-10
E1-09 E1-07
Frequency (Hz)
E2: Motor Parameters
Use E2 parameters to set motor-related data.
Sets the motor nameplate full load current in amperes
(A).
Automatically set during Auto-Tuning.
Sets the motor rated slip in Hertz.
Automatically set during rotational Auto-Tuning.
Sets the magnetizing current of the motor in Ampere.
Automatically set during rotational Auto-Tuning.
Sets the number of motor poles. Automatically set during
Auto-Tuning.
Sets the phase-to-phase motor resistance in ohms.
Automatically set during Auto-Tuning.
Sets the voltage drop due to motor leakage inductance as
a percentage of motor rated voltage.
Automatically set during Auto-Tuning.
Sets the motor iron saturation coefficient at 50% of
magnetic flux. Automatically set during Auto-Tuning.
Sets the motor iron saturation coefficient at 75% of
magnetic flux. Automatically set during Auto-Tuning.
Range
155 to 255
0.0 to 255.0
0.0 to E1-
0.0 to E1-
0.0 to 255.0
0.0 to E1-
0.0 to 255.0
0.0 to E1-
E1-06 E1-11 E1-04
0.0 to 255.0
0.0 to 255.0
10 to 200%
of drive
0 to less
than E2-01
0.000 to
0.0 to 40.0
0.00 to 0.50 0.50%
[E2-07] to
YASKAWA ELECTRIC SIEP C710606 44B YASKAWA AC Drive T1000V Technical Manual
Control
Mode
Def.
V/f OL V PM
200 V
S
S
F
F
A
A
40.0 to
50.0 Hz
400.0
S
S
<2> <9>
<14>
200.0 V
S
S
<2> <9>
50.0 Hz
S
S
04
<2> <9>
2.5 Hz
A
A
04
<2>
16.0 V
A
A
<2>
1.3 Hz
S
S
04
<2> <9>
12.0 V
A
A
<2>
0.0 Hz
A
A
04
<2>
0.0 V
A
A
<2>
0.0 V
A
S
<2>
rated
S
S
<33>
current
<20>
0.00 to
A
A
<33>
20.00
A
A
<33>
2 to 48
4 poles
A
A
65.000
A
A
<33>
<23>
A
A
<33>
A
0.75%
A
0.75
Addr. Hex Pg.
S
300
147
302
147
S
303
148
S
304
148
S
305
148
306
148
307
148
S
308
148
309
148
30A
148
30B
148
30C
148
30E
148
30F
149
310
149
311
149
312
149
313
149
314
150
315
150

Hide quick links: