12NC
960051150114
960051002589
960051103309
960051151220
960051150137
The following circuit cards are dedicated for usage in the IPS DM only.
12NC
960051150137
960051151252
960051151493
UNIVERGE NEAX 2000 IPS General Description
Issue 5
Description
PN-8LCAA
PN-8LCAD
10
PN-8LCAF
PN-4LLCB
11
PN-4LCAA
Description
PN-4LCAA
See Note
PN-PW03
PZ-4PFTA
X
-
- 8L ANALOGUE LINE CIRCUIT
• Loop Resistance: Max. 600ohms
• Message Waiting Control: 8 Circuits
• Momentary Open: 8 Circuits
X
-
- 8 Circuit Analog Station card
· Provides CLI display (FSK) on analog station,
together with PN-4RSTH
· CLI: 8 circuits
· Ring Trip: 8 circuits
· Loop Resistance: Max. 600 ohms
· Line Voltage: -27Vdc
· Available in R10 or later software
8-line Analog Station Card with Message Waiting
IndicationI (MWI)
- Polarity Reversal
- Loop resistance: Max. 600 ohms
- MWI - Polarity Reversal: 8 circuits
- Available with R11 or later software
- RoHS compliant
X
X
X Four-circuit Analogue Long Line Card for Single
Line Telephones:
Loop resistance for PB/DP:
• PB : Maximum 1200 ohms
• DP (20 PPS) : Maximum 1700 ohms
• DP (10 PPS) : Maximum 2500 ohms
Including the internal resistance of the distant office
equipment.
• Provides Message Waiting Lamp control, momentary
open/ reverse functions for each circuit.
• IPS= PZ-PW122 is required. Max 376 stations/ 94
cards per system
• DM & DMR= PN-PW03 is required. DM max 48
stations/12 cards per system. DMR max 32 stations/8
cards per system. DM & DMR require one PN-
4LCAA to be mounted per PIM to provide Ring
Generator to backplane.
•Loop Resistance: MAX. 2500 ohms (LLC)
-
X
X Four Circuit Analogue Station Card with Ring
Generator.
-
X
X Four Circuit Analogue Station Card with Ring
Generator
-
X
X -48V DC/DC Power Supply Card
Used with PN-4LLCB for long line.
Maximum one PN-PW03 per PIM
-
X
X Power Fail Transfer Circuit
CHAPTER 3 TERMINALS
Function
Function
Page 95