The Basic Module of the SOPHO 2000 IPS is the PIMMG (PBC). The system capacity is
defined by building configurations from 1 to maximum 8 PIMMG (with the 2000 IPS
SW 3200 Series R6.2). In case a dual processor configuration is required PIM 0 (First
PIM) should be a PIMMH; the PIMMH requires two SPN-CP27 processors.
The Basic Module of the SOPHO IPS DM is the PIMMD (PBC). The system capacity is
defined by building configurations from 1 to 3 PIMMD.
12NC
960051150006 ICS VS PIMMG(PBC):
960051153000 ICS VS PIMMH (PBC)
960051151121
960051151013
960051151348
960051151129
UNIVERGE NEAX 2000 IPS General Description
Issue 5
Description
SN1663 PIMMG
COVER PARTS
ASSEM(PBC)
PZ-PW126
AC CORD-B-A
PWR CNT CA-D
SIDE PANEL(EU)
LABEL BASE B
SN1664 PIMMH
COVER PARTS
ASSEM(PBC)
PZ-PW126
AC CORD-B-A
PWR CNT CA-E
SIDE PANEL(EU)
LABEL BASE B
ICS VS BASE (PBC)
SN1545 BASE
NP-254031 NAME
PLATE (CE)
TOP COVER ASSEM
PWR CNT CA-E
LABEL BASE B
PL-C.P.I.MSX3X8X3GF
(2 ea.)
48-TW-0.7 CONN CA
COVER PARTS ASSEM
(PBC)
ICS VS BATTMG (PBC)
SN1671 BATTMG
COVER PARTS
ASSEM (PBC)
LABEL BASE B
X
-
-
PIMMG
Port Interface Module (PIM) for single CPU
• Maximum 64 physical ports per PIM.
• 13 Card Slots (12 LT/AP Slots + 1 MP/FP Slot)
• Houses two batteries for protection from short power
interruption (for 30 minutes).
• At maximum configuration, the system consists of
eight PIMs
PIMMH
X
-
-
Port Interface Module (PIM) for Back-Up CPU:
(PIM0 only)
• Maximum 64 physical ports per PIM.
• 13 Card Slots (11 LT/AP slots + 2 MP slots)
• Houses two batteries for protection from short power
interruption (for 30 minutes).
• At maximum configuration, the system consists of one
PIMMH and seven PIMMG's
Base/Top Cover Assembly:
X
-
-
• One base and top cover assembly is required for
each stack.
• CE Marking label and EMC Class A Warning label are
put on the BASE.
BUS cable (connects PIMMG/PIMMH to PIMMG)
X
-
-
• Required for multiple PIM Configurations
• Used to connect PIM 0 to PIM 1, PIM 0 to PIM 2, PIM
2 to PIM 3, PIM 0 to PIM 4, PIM 4 to PIM 5,, PIM 4 to
PIM 6 AND PIM 6 to PIM 7.. Max. 7 cables per
system.
Triangle Corner for Front Cover
X
-
-
(INCLUDED WITH PIMMG and PIMMH)
External Battery Module
X
-
-
(PIM for mounting external batteries)
• Max 4 batteries, 4 x (166mm long x 175mm wide x
125mm high)
• Requires one BATT CA EXT per module.