Agilent Technologies 1670G Series User Manual page 554

Logic analyzers
Hide thumbs Also See for 1670G Series:
Table of Contents

Advertisement

Troubleshooting the LAN Connection
Troubleshooting the Initial Connection
Information on the Ethernet Statistics menu
Status Bits
Ether Address
The logic analyzer's Ethernet address. This value is set by the factory
and cannot be changed.
Subnet Mask
The subnet mask being used by the logic analyzer. The logic analyzer
queries the network for this value when it is turned on. The value
cannot be changed.
Transmit
Successful
Number of successfully transmitted packets.
Not
Number of packets not transmitted due to errors. The transmit not
successful
successful field is tied primarily to transmit deferrals and possible
hardware problems. If a packet is deferred (not because of a
collision), then the packet is given a delay and retransmission is
attempted. After 15 deferrals, the not successful field is incremented.
Deferred
Number of packets deferred due to network traffic. After 15 deferrals,
the not successful field is incremented.
Collisions
Number of packets that had to be retransmitted due to network
traffic.
Late collisions
Number of illegal collisions that have occurred after 51.2 ms from
either the first bit of preamble or from SFD (Start of Frame Delimiter).
No heartbeat
Number of packets where the transceiver fails to provide a collision
pulse.
Receive
Successful
Number of successfully received packets.
Missed
Number of packets that were dropped for lack of resources in the
packets
logic analyzer.
Bad CRC
Number of corrupt packets.
Frame align
Number of packets with frame alignment error.
error
554