5 To scroll through waveforms, select the large rectangle below the
Div field and use the knob.
The roll indicator appears at the top of the rectangle and the name of
the first waveform is highlighted. The highlight moves as you turn the
knob.
6 To insert waveforms, double-click on the large rectangle under
the Div field (sec/Div or states/Div). In the pop-up, select Insert,
and then select the labels and channels.
The Sequential field inserts all the channels of the label as individual
waveforms; the Bus field groups the waveforms; the Bit N field inserts
just the Nth bit. Waveforms are inserted after the currently highlighted
one.
7 To take measurements, select the Markers field and choose the
appropriate marker type.
The markers available depend on the type of analyzer and whether or
not tagging is enabled. Use markers to locate patterns quickly.
Using the Logic Analyzer
Using the Analyzer Menus