Notes
• Lines 010 through 044 can be sent as discrete remote control commands
or included in a single file (with the data) and loaded using the bus.
• Other format commands could be used in place of or in addition to line
030.
• The label sequence seen in lines 040 through 044 will result in a specific bit
assignment. A different ordering of the LABel commands would give a
different ordering to the bits.
• There is a space before the '#8' in line 050.
• The character count in line 050 is based on:
• 15 characters (10 digits, 4 blanks, 1 <lf>) each in lines 060, 080, 100,
110, and 120
• 3 characters in line 090
• 13 characters in line 070
• 1 character (the <lf>) in line 050
Format Specification
Clock Source: Internal
Vector Output Mode: Full Channel 100 Mbit/s
Clock Period: 10 ns
Clock Out Delay Setting: 0
Using the Pattern Generator
ASCII File Commands