Parameter
Web: DSP Template Mix Table
EMS: VoP Media Provisioning > General Settings
[DSPTemplates]
Web: DSP Version Template
Number
EMS: Version Template
Number
[DSPVersionTemplateNumber
]
Version 6.4
Note: Bandwidth Efficient mode is not supported; the mode is
always Octet-aligned.
This parameter table allows the device to use a combination of two
DSP templates and determines the percentage of DSP resources
allocated per DSP template.
The format of this parameter is as follows:
[DspTemplates]
FORMAT DspTemplates_Index =
DspTemplates_DspTemplateNumber,
DspTemplates_DspResourcesPercentage;
[\DspTemplates]
For example, to load DSP Template 1 to 50% of the DSPs, and
DSP Template 2 to the remaining 50%, the table is configured as
follows:
DspTemplates 0 = 1, 50;
DspTemplates 1 = 2, 50;
Notes:
The DSPVersionTemplateNumber parameter is ignored when
the DSPTemplates parameter is configured.
For a list of supported DSP templates, see DSP Templates on
page 821.
Determines the DSP template used by the device. Each DSP
template supports specific coders, channel capacity, and features.
The default is DSP template 0.
You can load different DSP templates to digital modules using the
syntax DSPVersionTemplateNumber=xy
where:
y = 0 to 5 for DSP templates of digital modules
Notes:
For this parameter to take effect, a device reset is required.
For a list of supported DSP templates, see DSP Templates on
page 821.