Low Voltage Power Supply Troubleshooting; Print Engine Lvps - Fuji Xerox Phaser 5500 Service Manual

Table of Contents

Advertisement

Low Voltage Power Supply Troubleshooting

Print Engine LVPS

Print Engine LVPS Troubleshooting Reference
Applicable Parts
LVPS
Engine Logic
Board
Image
Processor Board
Power Switch
Print Engine LVPS Troubleshooting Procedure
Step
Actions and Questions
1
Check AC supply voltage to the LVPS.
1. Remove the Upper Right Cover.
2. Turn the printer power On.
3. Measure AC voltage at the following test
points on the LVPS:
P/J1-1 <=> P/J1- 4
Is the voltage across pins 1 and 4 equal
to 120V or 220V (line voltage).
2
Check DC supply voltage to the I/P Board:
1. Remove the Upper Right Cover.
2. Turn the printer power On.
3. Measure the voltage at these points:
P/J 521- 1 <=> ground +3.3 V
P/J 521- 6 <=> ground +3.3 V
P/J 521- 3 <=> ground +5.0 V
Are the voltage levels correct?
General Troubleshooting
References
Engine Logic Board Plug/Jack locator (page 10-13)
Image Processor Board Plug/Jack Locator (page 10-14)
Print Engine LVPS Plug/Jack locator (page 10-16)
Print Engine LVPS Wiring Diagram (page 10-21)
PL8.1 Print Engine Electrical (page 9-40)
Yes
No
Go to Step 2.
Verify correct power
from the AC outlet.
Verify the power cord is
in good condition and
plugged into the Printer
and AC outlet. Verify
that the GFI Breaker is
not tripped. Verify
correct operation of the
printer power switch
and AC harness.
Go to Step 3.
Replace the LVPS
(page 8-92). If the
problem persists, verify
the wire harness to the
I/P Board. If the wiring
checks out, replace the
I/P Board (page 8-91).