Lower Critical Moving Lower De-assertion
■
Fan Sensors
The values reported for all fan-speed sensor readings are indicated in revolutions
per minute (RPMs). The sensors have an upper bound of 15 000 RPM.
Fan sensors can generate the following SEL events:
Lower Critical Moving Lower Assertion
■
Lower Critical Moving Lower De-assertion
■
Power-Supply Sensors
All power sensor readings are indicated in watts (W) and are defined within a range
of
0W to 600W.
Power sensors do not generate SEL events.
■
There are no thresholds for power sensors.
■
Management Controllers
One management-controller sensor represents the BMC. The management controller
has the following capabilities:
Global Initialization. The init agent enables the controller to generate
■
messages.
Device Capabilities. This device acts as all of the following:
■
■
■
■
■
■
■
Miscellaneous Sensors
The following additional sensors also are supported:
System Event
■
Event Logging Disabled
■
System Firmware Progress
■
Watchdog
■
70
Sun Fire V20z and Sun Fire V40z Servers—Server Management Guide • July 2005
Chassis Device
IPMB Event Receiver
FRU Inventory Device
SEL Device
SDR Repository Device
Sensor Device
Need help?
Do you have a question about the Fire V20z and is the answer not in the manual?