Operating the PGM and NEXT Selection Buttons From an
External Device
Caution
When using the CCU, the camera tally control is possible for the camera assigned
to source number 1 to 5. When the camera is assigned to source number 6, the
camera tally cannot be lit.
Notes
• When the video from a camera with the tally lit is being used for program
output, then if you press the FTB button, the tally goes off.
• If you open a file on the hard disk in the source viewer assigned to the video
from a camera with the tally lit, the tally goes off.
When you connect an external device to the FACTORY USE connector on the
unit, you can perform switching for the PGM and NEXT selection buttons from
the external device.
Refer to the following diagram to prepare the cables.
Sample circuit diagram (RM-BR300)
TALLY/CONTACT connector
Open-collector output
1
CAMERA 1
CAMERA 2
2
CAMERA 3
3
CAMERA 4
4
5
CAMERA 5
6
CAMERA 6
8,9
GND
RM-BR300
Caution
• Pull-up of all signal lines is necessary.
• On the unit, set [Trigger] under [Remote Switching] of [Video Utility] to
[Low Level].
• On the RM-BR300, set the TALLY/CONTACT switch to CONTACT.
1
Connect the external device to the FACTORY USE connector.
2
Press the MENU button.
+5V
1KΩ
1
2
3
4
5
6
7,8,14,15
Cable
* For details on other device models, consult your
dealer or your Sony service representative.
Using the FACTORY USE Connector
FACTORY USE connector
TTL input
GPI 0
GPI 1
GPI 2
GPI 3
GPI 4
GPI 5
GND
AWS-G500