Installing Power Trim Pump

1. Mount pump in desired location.
IMPORTANT: Make hydraulic connections as quickly as possible to prevent oil from
leaking out of system. Be careful not to cross-thread or overtighten hose fittings.
2. Connect hydraulic hoses to trim pump. Torque fittings to 125 Ib-in. (14 Nm).
3. Connect power trim pump control harness to trim pump.
4. Connect trim limit switch wires and secure with wire retainer and sta-strap.
a - Black Hose Fitting (UP Circuit)
b - Gray Hose Fitting (DOWN Circuit)
c - Control Harness
d -Tie-Strap
e - Trim Limit Switch Wire (with Blue Sleeve) To BLUE/WHITE Harness Wire
f - Trim Limit Switch Wire (with Purple Sleeve) To PURPLE/WHITE Harness Wire
g - Wire Retainer And Sta-Strap