Throttle Cable Installation And Adjustment - FNM HPEP 225 Installation Manual

Table of Contents

Advertisement

Throttle Cable Installation and Adjustment

IMPORTANT: Be sure that cables are routed in such a way as to avoid sharp bends
and/or avoid contact with moving parts. DO NOT fasten any items to throttle cables.
1. Place remote control lever in neutral / idle position.
2. Install cable end on the potentiometer and tighten with flat kasher and split pin.
3. Regulate the lenght of the cable with the cable clamp.
4. Tighten locknut until it touches the adjustment clamp.
a
e
b
a – Throttle Cable End (anchored with flat kasher and split in, not visible)
b – Potentiometer
c – Throttle Cable Clamp
d – Locknut and Flat Washer
e – Potentiometer Lever
5. Place remote control lever in full forward WOT position.
6. Place remote control lever in neutral / idle position. Ensure that injection pump lever
contacts idle screw. Readjust throttle cable barrel if necessary.
79