Installing Inner Transom Plate - FNM HPEP 225 Installation Manual

Table of Contents

Advertisement

Installing Inner Transom Plate

1. Insert wires, hoses and shift cable through appropriate openings in inner transom plate.
2. Position gimbal housing on transom and hold in place.
IMPORTANT: Tightening the transom assembly fasteners using an X-pattern torque
sequence. Tighten in small increments and go around the pattern several times until
the proper torque is achieved.
3. Secure transom assembly with hardware as shown. Torque to 23 Ib-ft (31 Nm).
IMPORTANT: Steering lever continuity circuit wire must be positioned as shown to
avoid stressing wire when steering lever moves.
a - Locknuts and Flat Washers (8)
b - Torque Sequence
c - Continuity Circuit Wire
41