STEERING CABLE SPECIFICATIONS
IMPORTANT: Power steering pump lugging (squealing) in a hard right turn (against lock)
may mean a steering cable has been installed that does not have the correct
dimensions.
a - Coupler Nut - 7/8 -14 UNF - 28 Thread
b -11-3/4 in. (298 mm) Min.
c - Interface Point
d -1/2 in. (12.7 mm) Max.
e –27/64 in. (10.7 mm) Min. Flat
f - 7/64 in. (3.1 mm) Min. Radius
g - 5/8 in. (15.9 mm) Max. Diameter End Fitting
h - 3/8 in. (9.5 mm)
i - 3/8 in. (9.8 mm) Diameter Through Hole (Chamfered Each Side)
j -1-3/8 in. (34.9 mm) Max
k - 5/8 in. (15.9 mm) Diameter Tube
I - Cable Travel:
- Mid-Travel Position -16-7/8 in. (429 mm)
- Total Travel To Be 8 in. (203 mm) Min. - 9 in (228 mm) Max
- Travel Each Side of Mid-Travel Position - 4 in. (102 mm ) Min. - 4-1/2 in.
(114 mm) Max.
a – Installation flange for the power steering cable
b – Center of the hole at the power steering cable end
c – Max. 543 mm (21-3/8 in.)
32