Communication Switch 11 – Not used (do not change the settings.)
Communication Switch 12 [SP No. 1-104-019]
No
FUNCTION
Memory transmission: Interval
0-7
between dialing attempts to
the same destination
Communication Switch 13 – Not used (do not change the settings.)
Communication Switch 14 [SP No. 1-104-021]
No
FUNCTION
Inch-to-mm conversion during
0
transmission
0: Disabled 1: Enabled
1-5 Not used
SM Appendix
COMMENTS
01 – FF (Hex) minutes
COMMENTS
0: In immediate transmission, data scanned in inch
format are transmitted without conversion.
In memory transmission, data stored in the SAF
memory in mm format are transmitted without
conversion.
Note: When storing the scanned data into SAF
memory, the fax unit always converts the data into
mm format.
1: The machine converts the scanned data or
stored data in the SAF memory to the format
which was specified in the set-up protocol
(DIS/NSF) before transmission.
Do not change the factory settings.