Protocol dump list output after
each communication
6
0: Off
1: On
7
Not used
System Switch 01 - Not used (Do not change the factory settings.)
System Switch 02 [SP No. 1-101-003]
No
FUNCTION
0-1 Not used
Force after transmission stall
2
0: Off
1: On
3-5 Not used
Memory read/write by RDS
Bit 7: 0, Bit 6: 0
Always disabled
Bit 7: 0, Bit 6: 1
6-7
User selectable
Bit 7: 1, Bit 6: 0
User selectable
Bit 7: 1, Bit 6: 1
Always enabled
SM Appendix
This is only used for communication
troubleshooting. It shows the content of the
transmitted facsimile protocol signals. Always
reset this bit to 0 after finishing testing.
If system switch 09 bit 6 is at "1", the list is only
printed if there was an error during the
communication.
Do not change the setting.
COMMENTS
Do not change these settings.
With this setting on, the machine resets itself
automatically if a transmission stalls and fails to
complete the job.
Do not change these settings.
(0,0): All RDS systems are always locked out.
(0,1), (1,0): Normally, RDS systems are locked
out, but the user can temporarily switch RDS on to
allow RDS operations to take place. RDS will
automatically be locked out again after a certain
time, which is stored in System Switch 03. Note
that if an RDS operation takes place, RDS will not
switch off until this time limit has expired.
(1,1): At any time, an RDS system can access the
machine.
7-11